Reduced Corneal Thickness Values in Postmenopausal Women With Dry Eye
PURPOSE:To study and compare the corneal thickness values of postmenopausal women with dry eye and postmenopausal women without dry eye. METHODS:The corneal thickness value of 30 postmenopausal women with dry eye (dry eye group; aged 52 to 55 years) and 32 postmenopausal women without dry eye (norma...
Gespeichert in:
Veröffentlicht in: | Cornea 2005-01, Vol.24 (1), p.39-44 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | PURPOSE:To study and compare the corneal thickness values of postmenopausal women with dry eye and postmenopausal women without dry eye.
METHODS:The corneal thickness value of 30 postmenopausal women with dry eye (dry eye group; aged 52 to 55 years) and 32 postmenopausal women without dry eye (normal group; aged 51 to 55 years) was analyzed with the Orbscan Topography System II. Each woman underwent a tear breakup test, the Schirmer test, fluorescein staining of the cornea, and an analysis of the meibomian gland by slit lamp before corneal thickness measurement. The statistical analysis was performed by means of the unpaired Student t test.
RESULTS:The mean corneal thickness value was significantly decreased in postmenopausal women with dry eye (P < 0.001 at each corneal location). The central cornea had the thinnest mean values in dry eyes and normal eyes (533.10 ± 4.74 μm and 547.63 ± 15.11 μm, respectively), whereas superonasal cornea had thicker mean values in both groups (632.43 ± 6.11 μm and 648.78 ± 14.98 μm in dry eye and normal eyes, respectively).
CONCLUSIONS:Postmenopausal women with dry eye have lower corneal thickness values than postmenopausal women without dry eye. Special care must be taken with these reduced corneal thickness values when selecting postmenopausal women for surgery involving corneal photoablation. |
---|---|
ISSN: | 0277-3740 1536-4798 |
DOI: | 10.1097/01.ico.0000138836.45070.0f |