Development and evaluation of a new ELISA for the detection and quantification of antierythropoietin antibodies in human sera

Assays for the analysis of antierythropoietin antibodies (anti-EPO Abs) currently suffer from a high degree of nonspecificity or are cumbersome and time consuming to perform. They are therefore not well suited for the analysis of large numbers of human sera samples, a task that has become increasing...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of immunological methods 2004-11, Vol.294 (1), p.101-110
Hauptverfasser: Hoesel, W., Gross, J., Moller, R., Kanne, B., Wessner, A., Müller, G., Müller, A., Gromnica-Ihle, E., Fromme, M., Bischoff, S., Haselbeck, A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Assays for the analysis of antierythropoietin antibodies (anti-EPO Abs) currently suffer from a high degree of nonspecificity or are cumbersome and time consuming to perform. They are therefore not well suited for the analysis of large numbers of human sera samples, a task that has become increasingly important due to an increase in the number of patients developing anti-EPO Abs. The objective of this study was to develop and validate a sensitive and specific ELISA for the determination of anti-EPO Abs that would suit these purposes. In this new double antigen bridging ELISA, anti-EPO Abs bind via one site to recombinant human erythropoietin (rhEPO)-biotin immobilized to streptavidin-coated microtiter plates (MTPs) and by a second site to rhEPO labelled with digoxigenin (DIG). The amount of bound antibody is determined using an anti-DIG antibody coupled to peroxidase. A rabbit polyclonal anti-EPO Ab purified by immunoadsorption is used as reference antibody preparation. The dynamic range of this ELISA was 1–75 ng/ml per assay calibrated with the reference antibody preparation. The assay was specific for anti-EPO Abs and did not react with other immunoglobulins (Ig) present in human serum. The lower limit of detection (LLD) of the assay was 0.5 ng/ml, and the lower limit of quantitation (LLQ) was 1.0 ng/ml. Anti-EPO Abs could be detected in the sera of pure red cell aplasia (PRCA) patients. In contrast to previous reports, no anti-EPO Abs could be detected in the sera of patients with systemic lupus erythematosus (SLE), rheumatoid arthritis (RA), Sjögren's syndrome (SS), or in the sera of dialysis patients.
ISSN:0022-1759
1872-7905
DOI:10.1016/j.jim.2004.08.017