Label-free detection of B. anthracis spores using a surface plasmon resonance biosensor
This study demonstrates the first use of surface plasmon resonance (SPR) technology for the rapid, sensitive and label-free detection of whole B. anthracis spores. The approach involves the use of an SPR biosensor (Biacore 3000), and a monoclonal antibody which was raised against the B. anthracis sp...
Gespeichert in:
Veröffentlicht in: | Analyst (London) 2009-04, Vol.134 (4), p.738-742 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study demonstrates the first use of surface plasmon resonance (SPR) technology for the rapid, sensitive and label-free detection of whole B. anthracis spores. The approach involves the use of an SPR biosensor (Biacore 3000), and a monoclonal antibody which was raised against the B. anthracis spore (mAb 8G3). By means of subtractive inhibition assays, whole B. anthracis spores with concentrations as low as 10(4) colony-forming units (CFU) ml(-1) can be detected within 40 min, and other related Bacillus spores, even in high concentrations, can be differentiated from B. anthracis spores. |
---|---|
ISSN: | 0003-2654 1364-5528 |
DOI: | 10.1039/b813038h |