LC-MS/MS and centrifugal ultrafiltration method for the determination of novobiocin in chicken, fish tissues, milk and human serum
We present a rapid and simple method for detecting novobiocin in biologic samples using a methanol-based extraction of the tissue matrix and liquid chromatography with electrospray tandem mass spectrometry (LC-ESI-MS/MS) on positive mode. The sample, prepared using centrifugal ultrafiltration with 5...
Gespeichert in:
Veröffentlicht in: | Journal of chromatography. B, Analytical technologies in the biomedical and life sciences Analytical technologies in the biomedical and life sciences, 2009-02, Vol.877 (4), p.461-464 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We present a rapid and simple method for detecting novobiocin in biologic samples using a methanol-based extraction of the tissue matrix and liquid chromatography with electrospray tandem mass spectrometry (LC-ESI-MS/MS) on positive mode. The sample, prepared using centrifugal ultrafiltration with 5.0% SDS, was directly injected into the LC-MS/MS. Chromatographic separation was performed on a TSK-GEL ODS 100
V column using 0.5% formic acid in water/methanol. The method was validated according to the Japanese Maximum Residue Limits recommendations. Detection was linear over a range of 5–100
ppb matrix solution (
r
>
0.998). Novobiocin recovery values from chicken (0.05
ppm) and fish tissues (0.05
ppm), milk (0.08
ppm), and human serum (0.05 and 0.01
ppm) samples ranged from 71
±
1 to 95
±
2%. |
---|---|
ISSN: | 1570-0232 1873-376X |
DOI: | 10.1016/j.jchromb.2008.12.039 |