An anthropomorphic phantom study of visualisation of surgical clips for partial breast irradiation (PBI) setup verification

Abstract Surgical clips were investigated for partial breast image-guided radiotherapy (IGRT). Small titanium clips were insufficiently well visualised. Medium tantalum clips were best for megavoltage IGRT and small tantalum clips were best for floor mounted kilovoltage IGRT (ExacTrac™). Both small...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiotherapy and oncology 2009-01, Vol.90 (1), p.56-59
Hauptverfasser: Thomas, Carys W, Nichol, Alan M, Park, Julie E, Hui, Jason F, Giddings, Alison A, Grahame, Sheri, Otto, Karl
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Surgical clips were investigated for partial breast image-guided radiotherapy (IGRT). Small titanium clips were insufficiently well visualised. Medium tantalum clips were best for megavoltage IGRT and small tantalum clips were best for floor mounted kilovoltage IGRT (ExacTrac™). Both small tantalum and medium titanium clips were suitable for isocentric kilovoltage IGRT.