Solid substrate-room temperature phosphorimetry for the determination of trace lead using p-nitro-phenyl-fluorone-multi-wall carbon nanotubes–Tween-80 micellae compound and diagnosis about human diseases
The structures of multi-wall carbon nanotubes (MWNTs) were modified by H 2SO 4–HNO 3 and H 2SO 4–H 2O 2, respectively. The corresponding products were water-soluble MWNTs-A and MWNTs-B. According to the experiment, it was found that MWNTs-B could emit stable solid substrate-room temperature phosphor...
Gespeichert in:
Veröffentlicht in: | Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy Molecular and biomolecular spectroscopy, 2009-02, Vol.72 (1), p.156-164 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The structures of multi-wall carbon nanotubes (MWNTs) were modified by H
2SO
4–HNO
3 and H
2SO
4–H
2O
2, respectively. The corresponding products were water-soluble MWNTs-A and MWNTs-B. According to the experiment, it was found that MWNTs-B could emit stable solid substrate-room temperature phosphorescence (RTP) on the surface of paper with Ag
+ as perturber. Under the conditions of 70
°C and 15
min, MWNTs-B can react with Tween-80 and
p-nitro-phenyl-fluorone (R) to form R-MWNTs-B–Tween-80 micellae compound, which could emit RTP of R and MWNTs-B on the surface of paper, respectively. Pb
2+ could cause the RTP of R and MWNTs-B enhanced sharply, respectively. Δ
I
p is directly proportional to the content of Pb
2+. A new solid substrate-room temperature phosphorimetry (SS-RTP) for the determination of trace Pb
2+ has been established based on R-MWNTs-B–Tween-80 micellae compound containing double luminescent molecule. The detection limit of this method were 0.035
ag Pb
2+
spot
−1 (8.8
×
10
−17
g Pb
2+
ml
−1, MWNTs-B) and 0.028
ag Pb
2+
spot
−1 (7.1
×
10
−17
g Pb
2+
ml
−1, R). This method is of high sensitivity, good selectivity, high precision and accuracy. It could be applied to determine trace Pb
2+ in serum samples at wavelength of 453.7/623.0
nm (R) or 475.9/645.0
nm (MWNTs-B) with satisfactory results, showing that SS-RTP has flexibility and utility value. Simultaneously, this method can be used to diagnose human diseases. The reaction mechanism for the determination of trace Pb
2+ by SS-RTP based on R-MWNTs-B–Tween-80 micellae compound containing double luminescent molecule was also discussed. |
---|---|
ISSN: | 1386-1425 |
DOI: | 10.1016/j.saa.2008.09.023 |