Tumor Imaging Using a Standardized Radiolabeled Adapter Protein Docked to Vascular Endothelial Growth Factor
Direct radiolabeling of proteins can result in the loss of targeting activity, requires highly customized procedures, and yields heterogeneous products. Here we describe a novel imaging complex comprised of a standardized (99m)Tc-radiolabeled adapter protein noncovalently bound to a "Docking ta...
Gespeichert in:
Veröffentlicht in: | The Journal of nuclear medicine (1978) 2004-08, Vol.45 (8), p.1373-1380 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Direct radiolabeling of proteins can result in the loss of targeting activity, requires highly customized procedures, and yields heterogeneous products. Here we describe a novel imaging complex comprised of a standardized (99m)Tc-radiolabeled adapter protein noncovalently bound to a "Docking tag" fused to a "Targeting protein". The assembly of this complex is based on interactions between human 109-amino acid (HuS) and 15-amino acid (Hu-tag) fragments of ribonuclease I, which serve as an "Adapter protein" and a Docking tag, respectively.
HuS modified with hydrazinonicotinamide (HYNIC) was radiolabeled using (99m)Tc-tricine to a specific activity of 3.4-7.4 MBq/microg. Protein complexes were then formed by mixing (99m)Tc-HuS with equimolar amounts of either Hu-tagged VEGF(121) (Hu-VEGF [vascular endothelial growth factor]) or Hu-tagged anti-VEGFR-2 single-chain antibody (Hu-P4G7) and incubating on ice for 15 min. 4T1 luc/gfp luciferase-expressing murine mammary adenocarcinoma cells (1 x 10(4)) were implanted subcutaneously or injected intravenously into BALB/c mice. Bioluminescent imaging (BLI) was performed 10 d later. Immediately after BLI visualization of tumor, 18.5-37 MBq of tracer (5-10 microg of protein) were injected via tail vein. One hour later planar or SPECT images were obtained, followed by killing the mice.
There was significantly (P = 0.0128) increased uptake of (99m)Tc-HuS/Hu-VEGF (n = 10) within subcutaneous tumor as compared with (99m)Tc-HuS/Hu-P4G7 (n = 5) at biodistribution assay (2.68 +/- 0.75 vs. 1.8 +/- 0.21; tumor-to-subcutaneous tissue [ratio of specific activities], respectively), despite similar molecular weights. The focal (99m)Tc-HuS/Hu-VEGF uptake seen on planar images (3.44 +/- 1.16 [tumor to soft-tissue background]) corresponded directly to the locations of tumor observed by BLI. Region of interest analyses of SPECT images revealed a significant increase of (99m)Tc-HuS/Hu-VEGF (n = 5) within the lungs with BLI-detectable pulmonary tumor nodules as compared with controls (n = 4) (right: 4.47 +/- 2.07 vs. 1.79 +/- 0.56; left: 3.66 +/- 1.65 vs. 1.62 +/- 0.45, tumor lung [counts/pixel]/normal lung [counts/pixel], respectively).
(99m)Tc-HuS/Hu-VEGF complex is stable for at least 1 h in vivo and can be effectively used to image mouse tumor neovasculature in lesions as small as several millimeters in soft tissue. We expect that a similar approach can be adapted for in vivo delivery of other targeting proteins of interest without aff |
---|---|
ISSN: | 0161-5505 1535-5667 |