Intracardiac Calipers for Artificial Chordae Replacement in Mitral Valve Repair

Length adjustment of artificial chordae is crucial in the outcome of anterior mitral valve repair. Herein, a simple and reproducible method of artificial chordal replacement using polytetrafluoroethylene suture is described. With this technique, the length of the neo-chordae is easily decided and th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 2009, Vol.87 (1), p.326-328
Hauptverfasser: Doi, Atsuo, MD, Iida, Hiroshi, MD, PhD, Sunazawa, Toru, MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Length adjustment of artificial chordae is crucial in the outcome of anterior mitral valve repair. Herein, a simple and reproducible method of artificial chordal replacement using polytetrafluoroethylene suture is described. With this technique, the length of the neo-chordae is easily decided and the knot can be tied surely without change in the length using only one instrument.
ISSN:0003-4975
1552-6259
DOI:10.1016/j.athoracsur.2008.05.033