Surgical open-chest ventricular defibrillation: triphasic waveforms are superior to biphasic waveforms

Triphasic shocks have been evaluated for endocardial defibrillation but not for open-chest epicardial defibrillation. The purpose of this study was to compare the efficacy and safety of biphasic versus triphasic shocks for epicardial defibrillation in a porcine model. Twenty-two adult swine (18-28 k...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Pacing and clinical electrophysiology 2004-07, Vol.27 (7), p.941-948
Hauptverfasser: Zhang, Yi, Boddicker, Kimberly A, Davies, Loyd R, Jones, Janice L, Kerber, Richard E
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Triphasic shocks have been evaluated for endocardial defibrillation but not for open-chest epicardial defibrillation. The purpose of this study was to compare the efficacy and safety of biphasic versus triphasic shocks for epicardial defibrillation in a porcine model. Twenty-two adult swine (18-28 kg) were deeply anesthetized and intubated. After 30 seconds electrically induced VF, each pig received truncated exponential biphasic (7.2-ms positive pulse duration and 7.2-ms negative pulse duration, total waveform duration 14.4 ms) and triphasic (4.8/4.8/4.8 ms, total waveform duration 14.4 ms) epicardial shocks. Pigs in group 1 (n = 11) received epicardial biphasic and triphasic shocks from large hand held paddle electrodes (44.2 cm2); pigs in group 2 (n = 11) received shocks from small paddle electrodes (15.9 cm2). Shocks were given at five selected energy levels (3-30 J) in random sequence. Four shocks were delivered at each energy level to construct an energy versus percentage of success curve. In group 1 (large paddle electrodes), percentage of shock success was significantly higher for triphasic shocks at the energy levels of 3, 5, 10, and 20 J compared to biphasic shocks. In group 2 (small paddle electrodes), triphasic shocks yielded a significantly higher percentage of shock success than biphasic shocks at the energy levels of 5, 10, and 20 J). Shock induced ventricular tachycardia was similar for both waveforms; asystole was rare. For open-chest defibrillation, triphasic waveform shocks were superior to biphasic waveform shocks for VF termination at energy levels of 3-20 J and were as safe as biphasic shocks.
ISSN:0147-8389
1540-8159
DOI:10.1111/j.1540-8159.2004.00563.x