Ionic dialysance allows an adequate estimate of urea distribution volume in hemodialysis patients

Ionic dialysance allows an adequate estimate of urea distribution volume in hemodialysis patients. An adequate estimation of urea distribution volume (V) in hemodialysis patients is useful to monitor protein nutrition. Direct dialysis quantification (DDQ) is the gold standard for determining V, but...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Kidney international 2004-08, Vol.66 (2), p.786-791
Hauptverfasser: Filippo, Salvatore D.I., Manzoni, Celestina, Andrulli, Simeone, Pontoriero, Giuseppe, Dell'Oro, Cesare, Milia, Vincenzo L.A., Tentori, Flavia, Crepaldi, Monica, Bigi, Maria Carla, Locatelli, Francesco
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Ionic dialysance allows an adequate estimate of urea distribution volume in hemodialysis patients. An adequate estimation of urea distribution volume (V) in hemodialysis patients is useful to monitor protein nutrition. Direct dialysis quantification (DDQ) is the gold standard for determining V, but it is impractical for routine use because it requires equilibrated postdialysis plasma water urea concentration. The single pool variable volume urea kinetic model (SPVV-UKM), recommended as a standard by Kidney Disease Outcomes Quality Initiative (K/DOQI), does not need a delayed postdialysis blood sample but it requires a correct estimate of dialyser urea clearance. Ionic dialysance (ID) may accurately estimate dialyzer urea clearance corrected for total recirculation. Using ID as input to SPVV-UKM, correct V values are expected when end-dialysis plasma water urea concentrations are determined in the end-of-session blood sample taken with the blood pump speed reduced to 50 mL/min for two minutes (Upwt2′). The aim of this study was to determine whether the V values determined by means of SPVV-UKM, ID, and Upwt2′ (VID) are similar to those determined by the “gold standard” DDQ method (VDDQ). Eighty-two anuric hemodialysis patients were studied. VDDQ was 26.3 ± 5.2 L; VID was 26.5 ± 4.8 L. The (VID–VDDQ) difference was 0.2 ± 1.6 L, which is not statistically significant (P = 0.242). Anthropometric volume (VA) calculated using Watson equations was 33.6 ± 6.0 L. The (VA–VDDQ) difference was 7.3 ± 3.3 L, which is statistically significant (P < 0.001). Anthropometric-based V values overestimate urea distribution volume calculated by DDQ and SPVV-UKM. ID allows adequate V values to be determined, and circumvents the problem of delayed postdialysis blood samples.
ISSN:0085-2538
1523-1755