Lack of Efficacy of Recombinant Human Thyrotropin Versus Thyroid Hormone Withdrawal for Radioiodine Therapy Imaging in a Patient with Differentiated Thyroid Carcinoma Lung Metastases
The treatment of lung metastases of thyroid cancer is nearly exclusively limited to the administration of iodine-131. For patients presented with micronodular lesions, the therapeutic response is often excellent, increasing life expectancy. Because of the necessity of multiple iodine-131 treatments...
Gespeichert in:
Veröffentlicht in: | Thyroid (New York, N.Y.) N.Y.), 2004-06, Vol.14 (6), p.465-467 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The treatment of lung metastases of thyroid cancer is nearly exclusively limited to the administration of iodine-131. For patients presented with micronodular lesions, the therapeutic response is often
excellent, increasing life expectancy. Because of the necessity of multiple iodine-131 treatments in the course of this therapy, and subsequently, the lack of tolerance of hormonal withdrawal, the use of
recombinant human thyrotropin (rhTSH) as a method of stimulation could represent an interesting alternative. However, as in the present case, the stimulation by rhTSH can be less effective than hormonal
withdrawal, as shown in the posttherapy scan to detect metastatic lesions and thus could be detrimental to the treatment efficiency. |
---|---|
ISSN: | 1050-7256 1557-9077 |
DOI: | 10.1089/105072504323150804 |