Test Results of the Third Japanese SULTAN Sample
Many full size conductors for the ITER TF coils have been tested at the SULTAN test facility in Switzerland for conductor qualification. JAEA tested two samples and two kinds of Nb 3 Sn strands were evaluated through the tests. Now another sample named JATF3 has been tested, which uses two other kin...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on applied superconductivity 2009-06, Vol.19 (3), p.1470-1473 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Many full size conductors for the ITER TF coils have been tested at the SULTAN test facility in Switzerland for conductor qualification. JAEA tested two samples and two kinds of Nb 3 Sn strands were evaluated through the tests. Now another sample named JATF3 has been tested, which uses two other kinds of Nb 3 Sn strands. The strands satisfy the critical current density J c requirement, but results of the conductor test were lower than our expectation. After the test, JAEA has been investigating the reason by X-ray CT scan and destructive inspection, and has found a possible reason. |
---|---|
ISSN: | 1051-8223 1558-2515 |
DOI: | 10.1109/TASC.2009.2017696 |