Sensitivity of electrode contact solutions and contact pressure in assessing electrical resistivity of concrete
This paper covers some aspects of the development of a simple and robust electrical resistivity test method which has the potential for assessing the durability of concrete. A simple low frequency AC end-to-end resistivity test was adopted as a laboratory test method and has the potential of being p...
Gespeichert in:
Veröffentlicht in: | Materials and structures 2008-05, Vol.41 (4), p.621-632 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper covers some aspects of the development of a simple and robust electrical resistivity test method which has the potential for assessing the durability of concrete. A simple low frequency AC end-to-end resistivity test was adopted as a laboratory test method and has the potential of being preferred as a quality control test in readymixed concrete plants. The test method forgoes the need for cast-in place electrodes or silver paint for electrode-concrete interface. The work presented here examines the sensitivity of electrode contact solutions and contact pressures at the electrode-concrete interface with the use of synthetic sponges. Five concretes conforming to C32/40 compressive strength class in BS EN206-1/BS 8500-1 made from five different cement types were investigated and the work highlighted the need for using a reference conductive contact solution and a contact pressure. |
---|---|