Design of magneto-rheological (MR) valve
Magneto-Rheological Fluid (“MRF”) technology has been successfully employed in various low and high volume automotive applications. Good understanding of specific design constraints is required to define and to optimize a magneto-rheological device. This article presents parametrical analyses with m...
Gespeichert in:
Veröffentlicht in: | Sensors and actuators. A. Physical. 2008-11, Vol.148 (1), p.211-223 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Magneto-Rheological Fluid (“MRF”) technology has been successfully employed in various low and high volume automotive applications. Good understanding of specific design constraints is required to define and to optimize a magneto-rheological device. This article presents parametrical analyses with magnetic simulations, of a magneto-rheological valve and a magneto-rheological orifice. Experimental rig assemblies of two different control devices have been designed, built and the performances have been evaluated experimentally. Controlled pressure drops, of 0.6
MPa @ 4.5
A at 5
cm
3/s in the orifice mode, and 1.5
MPa @ 4.5
A at 0
cm
3/s, in the valve mode, using MRF132-AD, have been achieved. The study shows that excellent features like the fast response and the contactless nature of MRF control are attractive for various control devices. |
---|---|
ISSN: | 0924-4247 1873-3069 |
DOI: | 10.1016/j.sna.2008.07.028 |