STUDY ON ASEISMIC SUSPENSION CEILING WITH STEEL FURRINGS
Collapse damages of suspended ceilings during recent severe earthquakes are focused as mentioned in references 3), 6). In order to establish aseismic design method of suspended ceiling, static lateral loading tests are conducted for both conventional and grid system ceilings that are partial models...
Gespeichert in:
Veröffentlicht in: | Journal of Structural and Construction Engineering (Transactions of AIJ) 2008/08/30, Vol.73(630), pp.1295-1302 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | jpn |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Collapse damages of suspended ceilings during recent severe earthquakes are focused as mentioned in references 3), 6). In order to establish aseismic design method of suspended ceiling, static lateral loading tests are conducted for both conventional and grid system ceilings that are partial models made of real components. Newly developed aseismic stiffeners are applied in the models and their availabilities are confirmed through the tests. Finally, evaluation formulas of buckling strength, which are based on Euler's formula, for combined bracing system are proposed. |
---|---|
ISSN: | 1340-4202 1881-8153 |
DOI: | 10.3130/aijs.73.1295 |