A study of generator system selection for large wind turbine generator system
This paper focuses on selection of wind turbine generation systems that include generators, converters, and gears. We study three systems: a permanent magnet generator (PMG) system, a doubly‐fed generator (DFG) system, and a synchronous generator (SYG) system in terms of the system efficiencies and...
Gespeichert in:
Veröffentlicht in: | Electrical engineering in Japan 2007-10, Vol.161 (1), p.51-57 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper focuses on selection of wind turbine generation systems that include generators, converters, and gears. We study three systems: a permanent magnet generator (PMG) system, a doubly‐fed generator (DFG) system, and a synchronous generator (SYG) system in terms of the system efficiencies and running costs. The system efficiencies and running costs are calculated by considering the relationship between wind power and wind conditions. According to these results, the one‐step gear PMG system is the best choice for a large wind turbine system. © 2007 Wiley Periodicals, Inc. Electr Eng Jpn, 161(1): 51–57, 2007; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/eej.20506 |
---|---|
ISSN: | 0424-7760 1520-6416 |
DOI: | 10.1002/eej.20506 |