Failure analysis of (+/-55(o))(3) filament wound composite pipes with an inclined surface crack under static internal pressure
This study conducts failure analysis of filament wound glass reinforced plastic (GRP) pipes made of E-glass/epoxy with an inclined surface crack under open-ended internal pressure. Test specimens are composed of six antisymmetric layers with (+ /-55(o))(3) winding angles. Tests have been performed a...
Gespeichert in:
Veröffentlicht in: | Composite structures 2010-01, Vol.92 (1), p.182-187 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study conducts failure analysis of filament wound glass reinforced plastic (GRP) pipes made of E-glass/epoxy with an inclined surface crack under open-ended internal pressure. Test specimens are composed of six antisymmetric layers with (+ /-55(o))(3) winding angles. Tests have been performed at seven different crack angles: 0(o),15(o),30(o),60(o),45(o),75(o), and 90(o), with crack-to-thickness ratio of a/t=0.50. The burst strengths of the specimens were determined, and the dependence of the burst strength on the crack angle was examined. |
---|---|
ISSN: | 0263-8223 |