Binary retention time method for rapid determination of competitive Langmuir isotherm parameters

A method, based on the equilibrium theory of chromatography, to estimate competitive Langmuir isotherm parameters by measuring the retention time of the two shock fronts from pulse injections of binary mixtures has been developed. This method eliminates the need for detector calibration and pure com...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Separation and purification technology 2009-06, Vol.67 (3), p.344-354
Hauptverfasser: Rajendran, Arvind, Chen, Wenda
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A method, based on the equilibrium theory of chromatography, to estimate competitive Langmuir isotherm parameters by measuring the retention time of the two shock fronts from pulse injections of binary mixtures has been developed. This method eliminates the need for detector calibration and pure component injections; and computational time required is significantly reduced allowing for rapid parameter estimations. The method has been tested on published results and it has been found that parameters obtained from this “binary retention time method” are comparable to those estimated from more rigorous techniques such as the inverse method. The effectiveness and limitations of this method in rapid determination of isotherm parameters are discussed.
ISSN:1383-5866
1873-3794
DOI:10.1016/j.seppur.2009.03.046