Mechanical and thermo-physical characterization of three-directional carbon fiber composites for W-7X and ITER

Carbon fiber composites (CFCs) are the first choice as plasma facing materials for the strike points of divertor targets for future nuclear fusion devices like WENDELSTEIN 7-X and ITER. For the application in these facilities several potential European 3D-CFCs were compared and qualified: (1) four m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Fusion engineering and design 2009-06, Vol.84 (7), p.1525-1530
Hauptverfasser: Pintsuk, G., Compan, J., Koppitz, T., Linke, J., Peacock, A.T., Pitzer, D., Rödig, M., Wikman, S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Carbon fiber composites (CFCs) are the first choice as plasma facing materials for the strike points of divertor targets for future nuclear fusion devices like WENDELSTEIN 7-X and ITER. For the application in these facilities several potential European 3D-CFCs were compared and qualified: (1) four material batches of NB31 produced by Snecma Propulsion Solide (SNECMA); (2) NB41, SNECMA, the upgraded version of NB31; (3) N31, SNECMA, which is densified by chemical vapor infiltration (CVI) instead of a final liquid pitch infiltration characteristic for NB31; (4) a new developmental 3D-CFC produced by DUNLOP. The characterization of the composites is comprised of thermo-physical measurements and tensile tests. The results are correlated to density and microstructure and summarized as follows: (1) NB41 provides the highest thermal conductivity in the ex-pitch direction of ∼375 W/(m K) at room temperature; (2) all material grades are, due to their heterogeneity, characterized by a relatively large scatter of mechanical properties; (3) the different densification process for N31 in comparison to NB31 has no influence on the material properties; (4) NB41 provides in all three directions a comparably high tensile strength with an average in the ex-pitch direction of ∼220 MPa; (5) the 3D-CFC from DUNLOP is comparable to NB41 but yet does not meet the specifications in the needling direction.
ISSN:0920-3796
1873-7196