Lateral stiffness of masonry infilled reinforced concrete (RC) frames with central opening
Window and door openings are inevitable parts of infill walls for functional reasons. Currently, publications like FEMA-273 and ATC-40 contain provisions for the calculation of stiffness of solid infilled frames mainly by modeling infill as a "diagonal strut." However, such provisions are...
Gespeichert in:
Veröffentlicht in: | Earthquake spectra 2008-08, Vol.24 (3), p.701-723 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Window and door openings are inevitable parts of infill walls for functional reasons. Currently, publications like FEMA-273 and ATC-40 contain provisions for the calculation of stiffness of solid infilled frames mainly by modeling infill as a "diagonal strut." However, such provisions are not provided for infilled frames with openings. The present study proposes a reduction factor for effective width of diagonal strut over that of the solid reinforced concrete (RC) infilled frame to calculate its initial lateral stiffness when a central window opening is present. The study is based on initial lateral stiffness which is taken at 10% of the lateral strength of the infilled frames. |
---|---|
ISSN: | 8755-2930 1944-8201 |
DOI: | 10.1193/1.2942376 |