Traffic-generated airborne particles in naturally ventilated multi-storey residential buildings of Singapore: Vertical distribution and potential health risks
The main objective of the study is to quantify the mass concentration exposure levels of fine traffic-generated particles (PM 2.5) at various heights of typical multi-storey public housing buildings located in close proximity, i.e. within 30 m and along a busy major expressway in Singapore. The seco...
Gespeichert in:
Veröffentlicht in: | Building and environment 2009-07, Vol.44 (7), p.1493-1500 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The main objective of the study is to quantify the mass concentration exposure levels of fine traffic-generated particles (PM
2.5) at various heights of typical multi-storey public housing buildings located in close proximity, i.e. within 30
m and along a busy major expressway in Singapore. The secondary objective is to compare the potential health risks of occupants in the buildings, associated with inhalation exposure of fine traffic-generated particulate matter, based on estimated dose rates and the lowest observed adverse effect levels (loael) at the various floors of these buildings. Two typical public housing buildings, both naturally ventilated residential apartment blocks, of point block configuration (22-storey) and slab block configuration (16-storey) were selected for the study. Particulate samples were collected for both mass and chemical analysis (OC/EC ratio) at three representative floors: the lower, the mid, and upper floors of the buildings. Key meteorological parameters such as wind speed, wind direction, ambient temperature, and relative humidity were also concurrently measured at the sampling locations. For the potential health risk analysis, the occupants have been divided into four age categories namely, infants, children (1 year), children (8–10 years) and adults. The analysis takes into account age-specific breathing rates, body weights for different age categories. Experimental results explicitly showed that PM
2.5 mean particle mass concentration was highest at the midfloors of both buildings when compared to those measured at upper and lower floors during a typical day. Although the lower floors were closest to traffic emissions, the mean particle mass concentration was lower there than that at the midfloors, which could presumably be due to the interception of PM
2.5 particles by tree leaves or the inflow of clean and drier air from higher altitude with lower aerosol burden mixing with the traffic-polluted air at the lower levels thus lowering the concentration at the lower floors similar to induced chimney effect or both. The upper floors had the least fine particulate matter mass concentration due to dilution following pronounced mixing of traffic-polluted air with ambient air. The only difference between both blocks is that at corresponding floors, the mass concentration levels for slab block is much higher than that of point block. This could be attributed to the configuration of the blocks. Observational data show the slab |
---|---|
ISSN: | 0360-1323 1873-684X |
DOI: | 10.1016/j.buildenv.2008.07.012 |