Internal Flow Measurement with LDV at Design Point of Contra-Rotating Axial Flow Pump

The adoption of the contra-rotating rotor has been proposed in response to a demand for the axial flow pump with higher specific speed. The internal flow field and blade rows interactions between the front and rear rotors should be considered in the design for higher performance and more stable oper...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nihon Kikai Gakkai rombunshuu. B hen 2008/05/25, Vol.74(741), pp.1091-1097
Hauptverfasser: SHIGEMITSU, Toru, FURUKAWA, Akinori, WATANABE, Satoshi, OKUMA, Kusuo, FUKUTOMI, Junichiro
Format: Artikel
Sprache:jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The adoption of the contra-rotating rotor has been proposed in response to a demand for the axial flow pump with higher specific speed. The internal flow field and blade rows interactions between the front and rear rotors should be considered in the design for higher performance and more stable operation, but has not been clarified yet. The flow field in contra-rotating axial flow pump was measured at various flow rates with the LDV and wall pressure measurements. In the present paper, the experimental and numerical results in the flow field between front and rear rotors are shown at the design flow rate and the flow behaviors are discussed, related on blade loading, blade tip leakage flow, wake and blade rows interaction.
ISSN:0387-5016
1884-8346
DOI:10.1299/kikaib.74.1091