A switching power amplifier with feedback for improving total harmonic distortion

A high efficiency and low distortion and switching power amplifier is proposed. We use feedback to reduce the total harmonic distortion (THD) and the DC output bias current. The experimental results show that the proposed circuit has 0.24% total harmonic distortion and 91% power efficiency while the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analog integrated circuits and signal processing 2008-06, Vol.55 (3), p.205-212
Hauptverfasser: Kao, Chia-Hsiung, Tsai, Ping-Yu, Lin, Wen-Pin, Chuang, Yao-Jen
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A high efficiency and low distortion and switching power amplifier is proposed. We use feedback to reduce the total harmonic distortion (THD) and the DC output bias current. The experimental results show that the proposed circuit has 0.24% total harmonic distortion and 91% power efficiency while the DC output bias current is 12 μA at 1.5 V supply voltage.
ISSN:0925-1030
1573-1979
DOI:10.1007/s10470-007-9047-7