antibody microarray, in multiwell plate format, for multiplex screening of foodborne pathogenic bacteria and biomolecules

Intoxication and infection caused by foodborne pathogens are important problems worldwide, and screening tests for multiple pathogens are needed because foods may be contaminated with multiple pathogens and/or toxic metabolites. We developed a 96-well microplate, multiplex antibody microarray method...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical and bioanalytical chemistry 2008-05, Vol.391 (2), p.497-506
Hauptverfasser: Gehring, Andrew G, Albin, David M, Reed, Sue A, Tu, Shu-I, Brewster, Jeffrey D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Intoxication and infection caused by foodborne pathogens are important problems worldwide, and screening tests for multiple pathogens are needed because foods may be contaminated with multiple pathogens and/or toxic metabolites. We developed a 96-well microplate, multiplex antibody microarray method to simultaneously capture and detect Escherichia coli O157:H7 and Salmonella enterica serovar Typhimurium (S. typhimurium), as well as a biomolecule (chicken immunoglobulin G or IgG employed as a proteinaceous toxin analog) in a single sample. Microarrayed spots of capture antibodies against the targeted analytes were printed within individual wells of streptavidin-coated polystyrene 96-multiwell microtiter plates and a sandwich assay with fluorescein- or Cy3-labeled reporter antibodies was used for detection. (Printing was achieved with a conventional microarray printing robot that was operated with custom-developed microplate arraying software.) Detection of the IgG was realized from ca. 5 to 25 ng/mL, and detection of E. coli O157:H7 and S. typhimurium was realized from ca. 10⁶ to 10⁹ and ca. 10⁷ to 10⁹ cells/mL, respectively. Multiplex detection of the two bacteria and the IgG in buffer and in culture-enriched ground beef filtrate was established with a total assay (including detection) time of ca. 2.5 h. Detection of S. typhimurium was largely unaffected by high concentrations of the other bacteria and IgG as well as the ground beef filtrate, whereas a small decrease in response was observed for E. coli O157:H7. The multiwell plate, multiplex antibody microarray platform developed here demonstrates a powerful approach for high-throughput screening of large numbers of food samples for multiple pathogens and toxins.
ISSN:1618-2642
1618-2650
DOI:10.1007/s00216-008-2044-6