PERFORMANCE IMPROVEMENT OF A SINGLE STAGE GM CRYOCOOLER AT 25 K

To meet the cooling demand of some HTS devices, Cryomech, Inc. has redesigned and improved a single stage GM cryocooler to have a maximum capacity at 25K. The losses in a rotary valve and a low temperature regenerator have been reduced. The improved GM cryocooler provides a cooling capacity of 109 W...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Wang, C, Gifford, P E
Format: Tagungsbericht
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To meet the cooling demand of some HTS devices, Cryomech, Inc. has redesigned and improved a single stage GM cryocooler to have a maximum capacity at 25K. The losses in a rotary valve and a low temperature regenerator have been reduced. The improved GM cryocooler provides a cooling capacity of 109 W at 25 K with an input power of 10.4 kW while running with the 50Hz electrical source.
ISSN:0094-243X
DOI:10.1063/1.2908557