EFFECT OF HEATED PERIMETER ON FORCED CONVECTION HEAT TRANSFER OF HE I AT A SUPERCRITICAL PRESSURE

The forced convection heat transfer coefficients were measured on two pairs of test plates all 6.0 mm in width and located face to face on inner walls of a rectangular duct. Each pair having length of 20 mm and 80 mm, respectively, was connected in series electrically. The rectangular duct was 420 m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Doi, D, Shiotsu, M, Shirai, Y, Hama, K
Format: Tagungsbericht
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The forced convection heat transfer coefficients were measured on two pairs of test plates all 6.0 mm in width and located face to face on inner walls of a rectangular duct. Each pair having length of 20 mm and 80 mm, respectively, was connected in series electrically. The rectangular duct was 420 mm in length and 5 mmX6 mm in inner cross section. The experiments were performed for inlet temperatures from 2.2 to 6.5 K, flow velocities from 0.1 to 5.6 m/s, and at a supercritical pressure of 2.8 atm. Comparison of the obtained Nusselt numbers with the former results with a single test plate showed the clear effect of a heated perimeter. Non-dimensional heat transfer equation including the effect of heated perimeter is presented.
ISSN:0094-243X
DOI:10.1063/1.2908464