EFFECT OF HEATED PERIMETER ON FORCED CONVECTION HEAT TRANSFER OF HE I AT A SUPERCRITICAL PRESSURE
The forced convection heat transfer coefficients were measured on two pairs of test plates all 6.0 mm in width and located face to face on inner walls of a rectangular duct. Each pair having length of 20 mm and 80 mm, respectively, was connected in series electrically. The rectangular duct was 420 m...
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The forced convection heat transfer coefficients were measured on two pairs of test plates all 6.0 mm in width and located face to face on inner walls of a rectangular duct. Each pair having length of 20 mm and 80 mm, respectively, was connected in series electrically. The rectangular duct was 420 mm in length and 5 mmX6 mm in inner cross section. The experiments were performed for inlet temperatures from 2.2 to 6.5 K, flow velocities from 0.1 to 5.6 m/s, and at a supercritical pressure of 2.8 atm. Comparison of the obtained Nusselt numbers with the former results with a single test plate showed the clear effect of a heated perimeter. Non-dimensional heat transfer equation including the effect of heated perimeter is presented. |
---|---|
ISSN: | 0094-243X |
DOI: | 10.1063/1.2908464 |