Wrinkled MXene-modified screen-printed electrodes for highly efficient sarcosine detection

MXenes are gaining immense attention owing to their robust conductivity, presence of favorable surface-functional groups and excellent hydrophilicity. Herein, a simple solution-based approach was adopted to functionalize few-layer thick MXene-Ti₃C₂Tₓ with chitosan (Chi) molecules, creating a stable...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biochemical engineering journal 2024-02, Vol.202, p.109151, Article 109151
Hauptverfasser: Karakuş, Selcan, Tumrani, Sadam Hussain, Kahyaoğlu, İbrahim Mizan, Soomro, Razium Ali, Sirajuddin, Alshammari, Riyadh H., Al-Kahtani, Abdullah A., Nafady, Ayman
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:MXenes are gaining immense attention owing to their robust conductivity, presence of favorable surface-functional groups and excellent hydrophilicity. Herein, a simple solution-based approach was adopted to functionalize few-layer thick MXene-Ti₃C₂Tₓ with chitosan (Chi) molecules, creating a stable electro-active screen-printed electrode (SPE) platform for the detection of sarcosine (SAR), a new biomarker for prostate cancer. In comparison to pristine MXene, the chitosan-functionalized Ti₃C₂Tₓ (MX-Chi/SPE) offered favorable surface functionalization for easy immobilization of sarcosine oxidase (SOₓ) enzymes, which led to the improved enzymatic oxidation of SAR. The detection mechanism relied upon the efficient reduction of enzymatically produced H₂O₂ over MX-Chi/SPE, enabling selective detection of SAR both in low (0.1 to 0.3µM) and high (1.5 to 3.5µM) concentration ranges, with an estimated limit of detection (LOD) values of 0.012µM and 0.14µM (S/N = 3), respectively. Due to its robust enzymatic configuration, the biosensor enabled selective detection of SAR even in the presence of interfering species like ascorbic acid, uric acid, and glucose. Furthermore, the biosensor demonstrated excellent signal repeatability and stability and effectively recovered spiked SAR levels (98-106%) from artificial urine samples. This approach demonstrated the successful integration of MXenes as redox-active materials in clinical biosensors with a simple electrode preparation procedure, which has the potential to be extended to other MXene compositions.
ISSN:1369-703X
DOI:10.1016/j.bej.2023.109151