Development and evaluation of an anatomically designed and 3D printed device to enhance orotracheal intubation success in rabbits by inexperienced veterinarians

To assess whether the use of a three-dimensional (3D) printed device enhances the success rate of orotracheal intubation in rabbits. Prospective, crossover randomized controlled trial. A total of six mixed-breed rabbits. A device to guide the endotracheal tube was designed based on computed tomograp...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Veterinary anaesthesia and analgesia 2023-05, Vol.50 (3), p.273-279
Hauptverfasser: Nejamkin, Pablo, Clausse, María, Landivar, Florencia, Lorenzutti, Matías A., Cavilla, Verónica, Viviani, Paula, Alvarez, Luis I., Del Sole, María J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To assess whether the use of a three-dimensional (3D) printed device enhances the success rate of orotracheal intubation in rabbits. Prospective, crossover randomized controlled trial. A total of six mixed-breed rabbits. A device to guide the endotracheal tube was designed based on computed tomography images and then manufactured using 3D printing. Rabbits were randomly assigned for intubation by two inexperienced veterinarians using the blind (BLI), borescope- (BOR) or device- (DEV) guided techniques. Success rate, number of attempts, time to success, injury scores and propofol dose were recorded and compared. Significance was considered when p < 0.05. Success rate was higher in DEV (58.3%) than in BLI (8.3%) (p < 0.023), but not different from that in BOR (41.6%). Total time until successful intubation was lower in DEV (45 ± 23 seconds) and BOR (85 ± 62 seconds) than in BLI (290 seconds; p < 0.006). Time for the successful attempt was lower for DEV (35 ± 10 seconds) and BOR (74 ± 43 seconds) than in BLI (290 seconds; p < 0.0001). The propofol dose required was lower for DEV (2.3 ± 1.2 mg kg–1) than for BLI (3.4 ± 1.6 mg kg–1) (p < 0.031), but not different from BOR (2.4 ± 0.9 mg kg–1). Number of attempts and oxygen desaturation events were not different among techniques (p < 0.051 and p < 0.326, respectively). Injury scores [median (range)] before and after attempts were different in BLI [0 versus 1 (0–3), p < 0.005] and BOR [0 (0–1) versus 1 (0–3), p < 0.002] but not in DEV [0 (0–2) versus 0 (0–3), p < 0.109]. The device facilitated orotracheal intubation with a time similar to the borescope-guided technique but faster than the traditional blind technique.
ISSN:1467-2987
1467-2995
DOI:10.1016/j.vaa.2023.03.001