Influence of storage solution, temperature, assay time and concentration on RT-qPCR nucleic acid detection for SARS-CoV-2 detection of SARS-CoV-2 by the RT-qPCR

Real-time reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) is an important method for the early diagnosis of coronavirus disease 2019 (COVID-19). This study investigated the effects of storage solution, temperature and detection time on severe acute respiratory syndrome coronav...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biochemical and biophysical research communications 2024-05, Vol.707, p.149726, Article 149726
Hauptverfasser: Su, Lingxuan, Lou, Yihan, Li, Jiaxuan, Mao, Haiyan, Li, Jianhua, Sun, Yi, Zhou, Biaofeng, Wu, Guangshang, Huang, Chen, Zhang, Yanjun, Chen, Keda
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Real-time reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) is an important method for the early diagnosis of coronavirus disease 2019 (COVID-19). This study investigated the effects of storage solution, temperature and detection time on severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleic acid detection by RT-qPCR. Various concentrations of SARS-CoV-2 were added to inactive and non-inactive storage solution and the viral suspensions were stored at various temperatures (room temperature, 4, −20 and −80 °C). Then, at five different detection time points, the Ct values were determined by RT-qPCR. Active and inactive storage solutions and storage temperature have a great impact on the detection of N gene of SARS-CoV-2 at different concentration corridors but have little impact on the ORF gene. The storage time has a greater impact on the N gene and ORF gene at high concentrations but has no effect on the two genes at low concentrations. In conclusion, storage temperature, storage time and storage status (inactivated, non-inactivated) have no effect on the nucleic acid detection of SARS-CoV-2 at the same concentration. For different concentrations of SARS-CoV-2, the detection of N gene is mainly affected. •Detection in the same concentration range is not affected by detection status.•The impact of detection status on the N gene is greater than that of the ORF gene.•The effect of storage time on both genes was obvious at high concentrations.
ISSN:0006-291X
1090-2104
1090-2104
DOI:10.1016/j.bbrc.2024.149726