Cu,Zr-BTC/CNT composite for electrochemical detection of endocrine disruptor bisphenol A

Endocrine disruptors that may be present in plastic wastes can leach into surface water, pollute the environment and our drinking water; they must be monitored. In this study, an electrochemical sensor based on a metal organic framework (Cu, Zr-BTC) combined with carbon nanotubes (CNT) was developed...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of materials science 2023-11, Vol.58 (43), p.16699-16713
Hauptverfasser: Tien, Nguyen Ngoc, Dat, Nguyen Tien, Manh, Nguyen Ba, Hieu, Nguyen Dinh, Tu, Vu Cam, Ngan, Nguyen Thi Thanh, Ha, Vu Thi Thu, Decorse, Philippe, Piro, Benoit, Thu, Vu Thi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Endocrine disruptors that may be present in plastic wastes can leach into surface water, pollute the environment and our drinking water; they must be monitored. In this study, an electrochemical sensor based on a metal organic framework (Cu, Zr-BTC) combined with carbon nanotubes (CNT) was developed for rapid on-site detection of bisphenol A—the most widely used monomer in plastics production. The Cu, Zr-BTC/CNT composite was first prepared by a solvothermal process in DMF solvent at 100 °C. For the first time, the Zr-based MOF with high proton conductivity was combined with Cu-based MOF with large active area in the same framework to provide an efficient platform for electrochemical detection. Morphological and structural studies revealed the coordination of Cu 2+ and Zr 4+ ions with organic ligands in a highly porous framework (active surface area up to 673 m 2  g −1 ). The use of highly conductive carbon nanotube material is to improve the recorded electrochemical signals. The developed bisphenol A sensor showed a linear response for bisphenol A concentrations from 2 to 50 µM, with a detection limit down to 0.5 µM and a sensitivity of 0.45 µA.µM −1  cm −2 . The sensors produced gave reproducible results (relative standard deviation of less than 7%) and were stable (relative standard deviation less than 12% after several days of storage). Tests on real samples were performed on Hanoi tap water and showed a satisfactory recovery (92–95%). The results were validated using high performance liquid chromatography. These results demonstrate the possibility of using such MOF materials in sensor applications. Graphical abstract
ISSN:0022-2461
1573-4803
DOI:10.1007/s10853-023-09083-1