Real-time energy and economic performance of the multi-zone photovoltaic-drive air conditioning system for an office building in a tropical climate

scheme of the on-grid photovoltaic HVAC system. [Display omitted] •Modeling of split-type HVAC systems, VRF, and Chiller with thermoaccumulation;•Energy performance analysis of photovoltaic air conditioning systems;•Compatibility between thermal load and photovoltaic generation in offices;•Energy th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Energy conversion and management 2023-12, Vol.297, p.117713, Article 117713
Hauptverfasser: Nobuyoshi Yamada Junior, Roberto, Antonio Villa Ochoa, Alvaro, de Novaes Pires Leite, Gustavo, Claudius Nunes Silva, Heber, Ângelo Peixoto da Costa, José, Tiba, Chigueru, Gabriel Carvalho de Oliveira, Edywin, Suemy Arruda Michima, Paula
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:scheme of the on-grid photovoltaic HVAC system. [Display omitted] •Modeling of split-type HVAC systems, VRF, and Chiller with thermoaccumulation;•Energy performance analysis of photovoltaic air conditioning systems;•Compatibility between thermal load and photovoltaic generation in offices;•Energy thermoaccumulation systems contribute to an increase in energy performance;•Photovoltaic air conditioning systems proposed reduced grid dependence by 87%; This article presents the air-conditioning performance analysis of an office building with thermal zones for the transient simulation of photovoltaic solar systems in a tropical climate. The study focuses on the correlation between air conditioning consumption and photovoltaic generation. The objective is to maximize the self-consumption of locally produced photovoltaic energy. The simulation and numerical analysis of the annual energy flow using a time interval resolution of 2 min was introduced as a novelty of the work to demonstrate the implementation of the proposed climatization technologies. The procedure developed was tested through 4 case studies where photovoltaic energy generation was scaled to meet the annual consumption demand of different air conditioners and considering the southern hemisphere climate conditions. The performance of the cases studied was evaluated considering an energetic point of view through metering of self-sufficiency and self-consumption of conditioners and a financial vision through indicators of Net Present Value, Internal Rate of Return, and Payback Period. It was possible to reduce energy by 96% at peak hours compared to the reference scenario using energy demand side management. From the energy point of view, the proposed cases proved to be viable. Regarding the economic aspects, the instances with the renewal of the splits and the central Variable Refrigerant Flow system presented the best financial indexes between 6 and 7 years of payback and internal rate of return of 22% and 21%, respectively.
ISSN:0196-8904
1879-2227
DOI:10.1016/j.enconman.2023.117713