The use of a hyperosmolar irrigation solution is safe in an equine stifle joint model but does not reduce joint swelling
OBJECTIVETo determine the following: (1) whether an irrigation solution that is hyperosmolar (HYPER) relative to synovial fluid decreases tissue extravasation during an arthroscopic protocol when compared to a relatively hypoosmolar solution, (2) the safety of a HYPER solution based on viability of...
Gespeichert in:
Veröffentlicht in: | American journal of veterinary research 2022-10, Vol.83 (10) |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | OBJECTIVETo determine the following: (1) whether an irrigation solution that is hyperosmolar (HYPER) relative to synovial fluid decreases tissue extravasation during an arthroscopic protocol when compared to a relatively hypoosmolar solution, (2) the safety of a HYPER solution based on viability of joint tissues following joint irrigation, and (3) if the use of a HYPER solution decreases water content in stifle joint tissue. ANIMALS8 adult horses. PROCEDURESA prospective, blinded, randomized controlled trial was performed to compare lactated Ringer's solution (LRS; 273 mOsm/L) and a HYPER (600 mOsm/L) irrigation solution for routine medial femorotibial joint (MFTJ) arthroscopy. Primary outcomes included quantification of periarticular fluid retention based on measured changes in defined stifle joint girth and ultrasonographic (US) criteria. Water content of tissue samples was assessed. The viability of articular cartilage was determined using a microscopic fluorescent cell viability staining system. RESULTSNo significant difference in postprocedural joint swelling was observed between LRS and HYPER treatment groups. Percent increments in femorotibial joint dimensions (mean ± SD) were seen in both treatment groups based on US (LRS, 83.9 ± 84.6%; HYPER, 131.2 ± 144.9%) and caliper measurements (LRS 5.5 ± 4.3%; HYPER 7.5 ± 5.8%) (P ≤ .05). Chondrocyte viability and tissue water content were maintained in both treatment groups, and differences were not statistically significant. CLINICAL RELEVANCEDoubling the osmolarity of an irrigation solution used routinely for arthroscopy does not result in detrimental effects on chondrocyte viability or tissue water content. However, use of a relatively HYPER irrigation solution did not attenuate procedural tissue swelling of the equine stifle joint. |
---|---|
ISSN: | 0002-9645 1943-5681 |
DOI: | 10.2460/ajvr.22.04.0074 |