A unified deep-learning framework for enhanced patient-specific quality assurance of intensity-modulated radiation therapy plans

Modern radiation therapy techniques, such as intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT), use complex fluence modulation strategies to achieve optimal patient dose distribution. Ensuring their accuracy necessitates rigorous patient-specific quality assura...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical physics (Lancaster) 2024-12
Hauptverfasser: Looe, Hui Khee, Reinert, Philipp, Carta, Julius, Poppe, Björn
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Modern radiation therapy techniques, such as intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT), use complex fluence modulation strategies to achieve optimal patient dose distribution. Ensuring their accuracy necessitates rigorous patient-specific quality assurance (PSQA), traditionally done through pretreatment measurements with detector arrays. While effective, these methods are labor-intensive and time-consuming. Independent calculation-based methods leveraging advanced dose algorithms provide a reduced workload but cannot account for machine performance during delivery. This study introduces a novel unified deep-learning (DL) framework to enhance PSQA. The framework can combine the strengths of measurement- and calculation-based approaches. A comprehensive artificial training dataset, comprising 400,000 samples, was generated based on a rigorous mathematical model that describes the physical processes of radiation transport and interaction within both the medium and detector. This artificial data was used to pretrain the DL models, which were subsequently fine-tuned with a measured dataset of 400 IMRT segments to capture the machine-specific characteristics. Additional measurements of five IMRT plans were used as the unseen test dataset. Within the unified framework, a forward prediction model uses plan parameters to predict the measured dose distributions, while the backward prediction model reconstructs these parameters from actual measurements. The former enables a detailed control point (CP)-wise analysis. At the same time, the latter facilitates the reconstruction of treatment plans from the measurements and, subsequently, dose recalculation in the treatment planning system (TPS), as well as an independent second check software (VERIQA). This method has been tested with an OD 1600 SRS and an OD 1500 detector array with distinct spatial resolution and detector arrangement in combination with a dedicated upsampling model for the latter. The final models could deliver highly accurate predictions of the measurements in the forward direction and the actual delivered plan parameters in the backward direction. In the forward direction, the test plans reached median gamma passing rates better than 94% for the OD 1600 SRS measurements. The upsampled OD 1500 measurements show similar performance with similar median gamma passing rates but a slightly higher variability. The 3D gamma passing rates from the comparisons bet
ISSN:2473-4209
2473-4209
DOI:10.1002/mp.17601