A deep learning method for total-body dynamic PET imaging with dual-time-window protocols

Prolonged scanning durations are one of the primary barriers to the widespread clinical adoption of dynamic Positron Emission Tomography (PET). In this paper, we developed a deep learning algorithm that capable of predicting dynamic images from dual-time-window protocols, thereby shortening the scan...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of nuclear medicine and molecular imaging 2024-12
Hauptverfasser: Ding, Wenxiang, Wang, Hanzhong, Qiao, Xiaoya, Li, Biao, Huang, Qiu
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Prolonged scanning durations are one of the primary barriers to the widespread clinical adoption of dynamic Positron Emission Tomography (PET). In this paper, we developed a deep learning algorithm that capable of predicting dynamic images from dual-time-window protocols, thereby shortening the scanning time. This study includes 70 patients (mean age ± standard deviation, 53.61 ± 13.53 years; 32 males) diagnosed with pulmonary nodules or breast nodules between 2022 to 2024. Each patient underwent a 65-min dynamic total-body [ F]FDG PET/CT scan. Acquisitions using early-stop protocols and dual-time-window protocols were simulated to reduce the scanning time. To predict the missing frames, we developed a bidirectional sequence-to-sequence model with attention mechanism (Bi-AT-Seq2Seq); and then compared the model with unidirectional or non-attentional models in terms of Mean Absolute Error (MAE), Bias, Peak Signal-to-Noise Ratio (PSNR), and Structural Similarity (SSIM) of predicted frames. Furthermore, we reported the comparison of concordance correlation coefficient (CCC) of the kinetic parameters between the proposed method and traditional methods. The Bi-AT-Seq2Seq significantly outperform unidirectional or non-attentional models in terms of MAE, Bias, PSNR, and SSIM. Using a dual-time-window protocol, which includes a 10-min early scan followed by a 5-min late scan, improves the four metrics of predicted dynamic images by 37.31%, 36.24%, 7.10%, and 0.014% respectively, compared to the early-stop protocol with a 15-min acquisition. The CCCs of tumor' kinetic parameters estimated with recovered full time-activity-curves (TACs) is higher than those with abbreviated TACs. The proposed algorithm can accurately generate a complete dynamic acquisition (65 min) from dual-time-window protocols (10 + 5 min).
ISSN:1619-7070
1619-7089
1619-7089
DOI:10.1007/s00259-024-07012-1