Reusable EWOD-based microfluidic system for active droplet generation

Droplets are essential in a wide range of microfluidic applications, but traditional passive droplet generation methods suffer from slow response speed and the need for precise flow rate adjustment. Here, we present an active droplet generation method through electrowetting-on-dielectric (EWOD). Ele...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Lab on a chip 2025-01, Vol.25 (2), p.225-234
Hauptverfasser: Park, Suhee, Ryu, Jaewook, Han, Ki-Ho
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 234
container_issue 2
container_start_page 225
container_title Lab on a chip
container_volume 25
creator Park, Suhee
Ryu, Jaewook
Han, Ki-Ho
description Droplets are essential in a wide range of microfluidic applications, but traditional passive droplet generation methods suffer from slow response speed and the need for precise flow rate adjustment. Here, we present an active droplet generation method through electrowetting-on-dielectric (EWOD). Electrowetting is a technique that uses an electric field to change the wettability of a surface. In our method, we apply an electric field to the laminar flow of the dispersed and continuous phases in a microchannel, which induces the discretization of the dispersed thread and leads to droplet formation. A key feature of the proposed active droplet-generating microfluidic device is the reusability of the EWOD actuation substrate, dramatically reducing operational costs. In addition, this approach offers significant advantages over passive methods, including fast response speeds, a wider range of droplet sizes, and greater control over droplet size. In addition, the ultrathin polymer film used in this device allows for a low electrowetting voltage, which helps to prevent damage to encapsulated cells. We believe that our active droplet generation method is a promising new method for generating droplets in microfluidic applications. It is faster, more versatile, and more precise than passive methods, making it ideal for a wide range of applications, including single-cell genomics and drug discovery.
doi_str_mv 10.1039/d4lc00744a
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3146669186</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3146669186</sourcerecordid><originalsourceid>FETCH-LOGICAL-c204t-fc88ce859362a7e54463e580696d7085443f7daea5a2055f098d04ace6419eb73</originalsourceid><addsrcrecordid>eNpd0E1Lw0AQBuBFFFurF3-ABLyIEJ3tfh9LWz-gUBDFY9jsTiQlaepuIvTfG23twdPMwMMw8xJySeGOAjP3nlcOQHFuj8iQcsVSoNocH3qjBuQsxhUAFVzqUzJgRioQVA3J_AW7aPMKk_n7cpbmNqJP6tKFpqi60pcuidvYYp0UTUisa8svTHxoNhW2yQeuMdi2bNbn5KSwVcSLfR2Rt4f56_QpXSwfn6eTRerGwNu0cFo71MIwObYKBeeSodAgjfQKdD-zQnmLVtgxCFGA0R64dSg5NZgrNiI3u72b0Hx2GNusLqPDqrJrbLqYMcqllIZq2dPrf3TVdGHdX9crIcAIrUSvbneqfzjGgEW2CWVtwzajkP2Em834Yvob7qTHV_uVXV6jP9C_NNk3pD5ywQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3155095875</pqid></control><display><type>article</type><title>Reusable EWOD-based microfluidic system for active droplet generation</title><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Park, Suhee ; Ryu, Jaewook ; Han, Ki-Ho</creator><creatorcontrib>Park, Suhee ; Ryu, Jaewook ; Han, Ki-Ho</creatorcontrib><description>Droplets are essential in a wide range of microfluidic applications, but traditional passive droplet generation methods suffer from slow response speed and the need for precise flow rate adjustment. Here, we present an active droplet generation method through electrowetting-on-dielectric (EWOD). Electrowetting is a technique that uses an electric field to change the wettability of a surface. In our method, we apply an electric field to the laminar flow of the dispersed and continuous phases in a microchannel, which induces the discretization of the dispersed thread and leads to droplet formation. A key feature of the proposed active droplet-generating microfluidic device is the reusability of the EWOD actuation substrate, dramatically reducing operational costs. In addition, this approach offers significant advantages over passive methods, including fast response speeds, a wider range of droplet sizes, and greater control over droplet size. In addition, the ultrathin polymer film used in this device allows for a low electrowetting voltage, which helps to prevent damage to encapsulated cells. We believe that our active droplet generation method is a promising new method for generating droplets in microfluidic applications. It is faster, more versatile, and more precise than passive methods, making it ideal for a wide range of applications, including single-cell genomics and drug discovery.</description><identifier>ISSN: 1473-0197</identifier><identifier>ISSN: 1473-0189</identifier><identifier>EISSN: 1473-0189</identifier><identifier>DOI: 10.1039/d4lc00744a</identifier><identifier>PMID: 39670517</identifier><language>eng</language><publisher>England: Royal Society of Chemistry</publisher><subject>Actuation ; Addition polymerization ; Damage prevention ; Droplets ; Electric fields ; Laminar flow ; Microchannels ; Microfluidic devices ; Polymer films ; Wettability</subject><ispartof>Lab on a chip, 2025-01, Vol.25 (2), p.225-234</ispartof><rights>Copyright Royal Society of Chemistry 2025</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c204t-fc88ce859362a7e54463e580696d7085443f7daea5a2055f098d04ace6419eb73</cites><orcidid>0000-0002-9102-1581</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39670517$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Park, Suhee</creatorcontrib><creatorcontrib>Ryu, Jaewook</creatorcontrib><creatorcontrib>Han, Ki-Ho</creatorcontrib><title>Reusable EWOD-based microfluidic system for active droplet generation</title><title>Lab on a chip</title><addtitle>Lab Chip</addtitle><description>Droplets are essential in a wide range of microfluidic applications, but traditional passive droplet generation methods suffer from slow response speed and the need for precise flow rate adjustment. Here, we present an active droplet generation method through electrowetting-on-dielectric (EWOD). Electrowetting is a technique that uses an electric field to change the wettability of a surface. In our method, we apply an electric field to the laminar flow of the dispersed and continuous phases in a microchannel, which induces the discretization of the dispersed thread and leads to droplet formation. A key feature of the proposed active droplet-generating microfluidic device is the reusability of the EWOD actuation substrate, dramatically reducing operational costs. In addition, this approach offers significant advantages over passive methods, including fast response speeds, a wider range of droplet sizes, and greater control over droplet size. In addition, the ultrathin polymer film used in this device allows for a low electrowetting voltage, which helps to prevent damage to encapsulated cells. We believe that our active droplet generation method is a promising new method for generating droplets in microfluidic applications. It is faster, more versatile, and more precise than passive methods, making it ideal for a wide range of applications, including single-cell genomics and drug discovery.</description><subject>Actuation</subject><subject>Addition polymerization</subject><subject>Damage prevention</subject><subject>Droplets</subject><subject>Electric fields</subject><subject>Laminar flow</subject><subject>Microchannels</subject><subject>Microfluidic devices</subject><subject>Polymer films</subject><subject>Wettability</subject><issn>1473-0197</issn><issn>1473-0189</issn><issn>1473-0189</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2025</creationdate><recordtype>article</recordtype><recordid>eNpd0E1Lw0AQBuBFFFurF3-ABLyIEJ3tfh9LWz-gUBDFY9jsTiQlaepuIvTfG23twdPMwMMw8xJySeGOAjP3nlcOQHFuj8iQcsVSoNocH3qjBuQsxhUAFVzqUzJgRioQVA3J_AW7aPMKk_n7cpbmNqJP6tKFpqi60pcuidvYYp0UTUisa8svTHxoNhW2yQeuMdi2bNbn5KSwVcSLfR2Rt4f56_QpXSwfn6eTRerGwNu0cFo71MIwObYKBeeSodAgjfQKdD-zQnmLVtgxCFGA0R64dSg5NZgrNiI3u72b0Hx2GNusLqPDqrJrbLqYMcqllIZq2dPrf3TVdGHdX9crIcAIrUSvbneqfzjGgEW2CWVtwzajkP2Em834Yvob7qTHV_uVXV6jP9C_NNk3pD5ywQ</recordid><startdate>20250114</startdate><enddate>20250114</enddate><creator>Park, Suhee</creator><creator>Ryu, Jaewook</creator><creator>Han, Ki-Ho</creator><general>Royal Society of Chemistry</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-9102-1581</orcidid></search><sort><creationdate>20250114</creationdate><title>Reusable EWOD-based microfluidic system for active droplet generation</title><author>Park, Suhee ; Ryu, Jaewook ; Han, Ki-Ho</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c204t-fc88ce859362a7e54463e580696d7085443f7daea5a2055f098d04ace6419eb73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2025</creationdate><topic>Actuation</topic><topic>Addition polymerization</topic><topic>Damage prevention</topic><topic>Droplets</topic><topic>Electric fields</topic><topic>Laminar flow</topic><topic>Microchannels</topic><topic>Microfluidic devices</topic><topic>Polymer films</topic><topic>Wettability</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Park, Suhee</creatorcontrib><creatorcontrib>Ryu, Jaewook</creatorcontrib><creatorcontrib>Han, Ki-Ho</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Lab on a chip</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Park, Suhee</au><au>Ryu, Jaewook</au><au>Han, Ki-Ho</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reusable EWOD-based microfluidic system for active droplet generation</atitle><jtitle>Lab on a chip</jtitle><addtitle>Lab Chip</addtitle><date>2025-01-14</date><risdate>2025</risdate><volume>25</volume><issue>2</issue><spage>225</spage><epage>234</epage><pages>225-234</pages><issn>1473-0197</issn><issn>1473-0189</issn><eissn>1473-0189</eissn><abstract>Droplets are essential in a wide range of microfluidic applications, but traditional passive droplet generation methods suffer from slow response speed and the need for precise flow rate adjustment. Here, we present an active droplet generation method through electrowetting-on-dielectric (EWOD). Electrowetting is a technique that uses an electric field to change the wettability of a surface. In our method, we apply an electric field to the laminar flow of the dispersed and continuous phases in a microchannel, which induces the discretization of the dispersed thread and leads to droplet formation. A key feature of the proposed active droplet-generating microfluidic device is the reusability of the EWOD actuation substrate, dramatically reducing operational costs. In addition, this approach offers significant advantages over passive methods, including fast response speeds, a wider range of droplet sizes, and greater control over droplet size. In addition, the ultrathin polymer film used in this device allows for a low electrowetting voltage, which helps to prevent damage to encapsulated cells. We believe that our active droplet generation method is a promising new method for generating droplets in microfluidic applications. It is faster, more versatile, and more precise than passive methods, making it ideal for a wide range of applications, including single-cell genomics and drug discovery.</abstract><cop>England</cop><pub>Royal Society of Chemistry</pub><pmid>39670517</pmid><doi>10.1039/d4lc00744a</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0002-9102-1581</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1473-0197
ispartof Lab on a chip, 2025-01, Vol.25 (2), p.225-234
issn 1473-0197
1473-0189
1473-0189
language eng
recordid cdi_proquest_miscellaneous_3146669186
source Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection
subjects Actuation
Addition polymerization
Damage prevention
Droplets
Electric fields
Laminar flow
Microchannels
Microfluidic devices
Polymer films
Wettability
title Reusable EWOD-based microfluidic system for active droplet generation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-11T09%3A39%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reusable%20EWOD-based%20microfluidic%20system%20for%20active%20droplet%20generation&rft.jtitle=Lab%20on%20a%20chip&rft.au=Park,%20Suhee&rft.date=2025-01-14&rft.volume=25&rft.issue=2&rft.spage=225&rft.epage=234&rft.pages=225-234&rft.issn=1473-0197&rft.eissn=1473-0189&rft_id=info:doi/10.1039/d4lc00744a&rft_dat=%3Cproquest_cross%3E3146669186%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3155095875&rft_id=info:pmid/39670517&rfr_iscdi=true