A nanoporous electrochemical aptamer-based sensors for rapid detection of cardiac troponin I in blood
Acute myocardial infarction (AMI) is one of the top contributors to global disease mortality. AMI biomarkers, such as cardiac troponin I (cTnI), are often detected with enzyme-linked immunosorbent assay (ELISA) that suffers from several well-known drawbacks such as poor stability and slow and cumber...
Gespeichert in:
Veröffentlicht in: | Talanta (Oxford) 2025-03, Vol.284, p.127250, Article 127250 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Acute myocardial infarction (AMI) is one of the top contributors to global disease mortality. AMI biomarkers, such as cardiac troponin I (cTnI), are often detected with enzyme-linked immunosorbent assay (ELISA) that suffers from several well-known drawbacks such as poor stability and slow and cumbersome operation. Therefore, it is necessary to develop a new analytical technique that can rapidly analyse and detect cTnI for early screening of AMI. In this work, a nanoporous electrochemical aptamer-based (E-AB) sensor for rapid and sensitivite detect of cTnI was designed. Firstly, the aptamer was truncated, and then molecular docking simulation and circular dichroism (CD) were used to screen for aptamers with significant conformational changes when binding to the target, in order to enhance the sensitivity of E-AB sensors. Subsequently, nanoporous electrodes with active area 20 times higher than that of smooth electrodes were fabricated by electrochemical alloying/dealloying, which enabled E-AB sensors to obtain higher signal-to-noise ratios, providing favorable assurance for the detection results. Under optimal conditions, E-AB sensors could specifically detect cTnI in serum and blood with a detection limit of 1 pg/mL. At the same time, the sensor and enzyme-linked immunoassay (ELISA) had identical detection results when measuring target levels from real clinical samples. Furthermore, the sensor exhibited good reproducibility, stability, providing a simple and low-cost method for detecting cTnI, which is expected to help early AMI patients obtain accurate diagnosis.
[Display omitted]
•The binding energy of aptamers to cTnI was calculated by molecular docking simulation to screen the aptamers.•The nanoporous E-AB sensor was prepared by electrochemical alloying/dealloying technique.•The E-AB sensor can detect cTnI with high sensitivity and speed to meet the needs of clinical testing.•The sensor can detect cTnI in complex biological fluids and can be used for AMI early screening. |
---|---|
ISSN: | 0039-9140 1873-3573 1873-3573 |