Sling Results in Better Sleep Quality and Less Anxiety Early After Arthroscopic Rotator Cuff Repair: A Randomized Single-Blinded Trial
Sleep disturbance is commonly reported by patients wearing an abduction brace after arthroscopic rotator cuff repair (ARCR). Although a sling has been proven noninferior to an abduction brace for function and repair integrity, there is no evidence-based medical support for the advantage of the sling...
Gespeichert in:
Veröffentlicht in: | The American journal of sports medicine 2024-11, p.3635465241293057 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Sleep disturbance is commonly reported by patients wearing an abduction brace after arthroscopic rotator cuff repair (ARCR). Although a sling has been proven noninferior to an abduction brace for function and repair integrity, there is no evidence-based medical support for the advantage of the sling in improving sleep quality compared with a brace.
This study aimed to compare the effects of a sling and an abduction brace on sleep quality and clinical outcomes after ARCR. It was hypothesized that immobilization in a sling would result in better sleep quality while not deteriorating clinical outcomes and bone-tendon healing compared with an abduction brace.
Randomized controlled trial; Level of evidence, 1.
A total of 142 consecutive patients with rotator cuff tears were randomly assigned to 2 groups: (1) the brace group, receiving abduction brace immobilization for 6 weeks, and (2) the sling group, receiving sling immobilization after ARCR for 6 weeks. The primary outcome was the Pittsburgh Sleep Quality Index at 6 weeks postoperatively. Secondary outcomes-American Shoulder and Elbow Surgeons score, Self-rating Anxiety Scale, pain, satisfaction, and tendon healing (using ultrasonography)-were evaluated until 1 year postoperatively.
Complete outcome measurements were obtained for 131 patients. The Pittsburgh Sleep Quality Index at 6 weeks was 11.1 ± 2.7 for the brace group and 9.2 ± 2.3 for the sling group (
< .001), indicating a statistically significant advantage for the sling group. The sling group also reported significantly lower Self-rating Anxiety Scale, lower pain level, and higher satisfaction scores at 6 weeks. No significant difference was observed in outcome measures between groups at 1 year. The tendon healing rates (91% vs 88%, respectively) were comparable between the brace and sling groups within the first 1 year (risk ratio, 1.03 [95% CI, 0.92-1.16];
= .59).
The use of a sling resulted in better sleep quality, less anxiety, and higher satisfaction compared with an abduction brace in the first 6 weeks after ARCR; nevertheless, functional outcomes and repair integrity were similar at 1 year postoperatively between the 2 groups. These findings indicate that a sling is appropriate for the postoperative care of ARCR. However, caution should be used when interpreting these results because the clinical relevance of sling-related benefits warrants further investigation.
ChiCTR2200059967 (Chinese Clinical Trial Registry). |
---|---|
ISSN: | 0363-5465 1552-3365 1552-3365 |
DOI: | 10.1177/03635465241293057 |