Performance of Continuous Glucose Monitoring System Among Patients With Acute Ischaemic Stroke Treated With Mechanical Thrombectomy

Glucose metabolism abnormalities are prevalent in acute ischaemic stroke (AIS) patients and are associated with poor prognosis. The continuous glucose monitoring (CGM) system can provide detailed information on glucose levels and glycaemic excursions. This study aimed to evaluate the feasibility and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Diabetes/metabolism research and reviews 2024-11, Vol.40 (8), p.e70001
Hauptverfasser: Shi, Jie, Weng, Jiahao, Ding, Yu, Xia, Yue, Zhou, Yongwen, Wang, Xulin, Zhang, Feng, Zhang, Pan, Luo, Sihui, Zheng, Xueying, Liu, Xinfeng, Wang, Chaofan, Sun, Wen, Weng, Jianping
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Glucose metabolism abnormalities are prevalent in acute ischaemic stroke (AIS) patients and are associated with poor prognosis. The continuous glucose monitoring (CGM) system can provide detailed information on glucose levels and glycaemic excursions. This study aimed to evaluate the feasibility and accuracy of CGM application in the acute phase of AIS patients.AIMSGlucose metabolism abnormalities are prevalent in acute ischaemic stroke (AIS) patients and are associated with poor prognosis. The continuous glucose monitoring (CGM) system can provide detailed information on glucose levels and glycaemic excursions. This study aimed to evaluate the feasibility and accuracy of CGM application in the acute phase of AIS patients.This single-centre, prospective, and observational study consecutively enrolled patients with AIS with anterior circulation large vessel occlusion (AC-LVO) and received mechanical thrombectomy (MT) within 24 h of symptom onset. A user-retrospectively calibrated iPro2 CGM system was implanted right before the MT procedure started and removed on the fifth day after MT or at discharge. Fingertip glucose was measured as a reference. Accuracy evaluation included the Bland-Altman plot (with a proportion of CGM values within 15/15, 20/20 and 30/30), the absolute relative difference (ARD) and error grid analysis (EGA). The safety and glucose profiles were also evaluated.METHODSThis single-centre, prospective, and observational study consecutively enrolled patients with AIS with anterior circulation large vessel occlusion (AC-LVO) and received mechanical thrombectomy (MT) within 24 h of symptom onset. A user-retrospectively calibrated iPro2 CGM system was implanted right before the MT procedure started and removed on the fifth day after MT or at discharge. Fingertip glucose was measured as a reference. Accuracy evaluation included the Bland-Altman plot (with a proportion of CGM values within 15/15, 20/20 and 30/30), the absolute relative difference (ARD) and error grid analysis (EGA). The safety and glucose profiles were also evaluated.Of the 183 patients screened, 141 were included, with a median monitoring duration of 4.49 days. Compared to reference measurements, 3097 CGM readings were matched with a mean bias of -4.16 mg/dL. The proportions of sensor readings meeting the 15/15, 20/20 and 30/30 criteria were 64.55%, 76.07% and 87.21%, respectively. The overall mean and median ARD were 14.60% ± 14.62% and 9.77% (4.15, 20.00). EGA showed that 98.
ISSN:1520-7552
1520-7560
1520-7560
DOI:10.1002/dmrr.70001