Environmentally friendly screen-printed electrodes for the selective detection of 4-bromo-2,5-dimethoxyphenethylamine (2C-B) in forensic analysis
In response to the growing need for sustainable analytical methods, this study explores the repurposing of screen-printed electrodes (SPEs) that would otherwise be discarded. This involves recoating the working electrode surface with a graphite (Gr) and chitosan (CTS) dispersion, creating a reusable...
Gespeichert in:
Veröffentlicht in: | Analytical methods 2024-11, Vol.16 (44), p.7633-7642 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In response to the growing need for sustainable analytical methods, this study explores the repurposing of screen-printed electrodes (SPEs) that would otherwise be discarded. This involves recoating the working electrode surface with a graphite (Gr) and chitosan (CTS) dispersion, creating a reusable SPE (SPE-Gr/CTS). Demonstrating its utility, SPE-Gr/CTS was employed for the detection of 4-bromo-2,5-dimethoxyphenethylamine (2C-B), a phenylethylamine commonly used for recreational proposes. Identifying 2C-B in fluid oral and seized samples is of great interest for forensic and toxicological applications. The 2C-B detection using SPE-Gr/CTS was optimized in Britton-Robinson buffer solution (0.1 mol L
) at pH 2.0, employing square-wave adsorptive stripping voltammetry. The electrochemical behavior of 2C-B on SPE-Gr/CTS exhibited one irreversible oxidation and a reversible redox process. The proposed method presented a dynamic linear range for 2C-B determination (0.05 to 7.5 μmol L
) with a low LOD (0.015 μmol L
). Moreover, the stability of 2C-B electrochemical responses on SPE-Gr/CTS was confirmed using the same or different electrodes (
= 3), with a relative standard deviation of less than 5.0%. Interference studies with seventeen other illicit drugs and adulterants demonstrated that the proposed method is selective for 2C-B detection even in the presence of these substances. Real seized and oral fluid samples containing 2C-B were analyzed using this method, and the results were confirmed by LC-MS. The proposed device demonstrates to be an environmentally friendly and selective sensor for 2C-B detection in forensic analysis, offering a rapid and straightforward screening method for seized and biological samples. In addition, a portable and sensitive determination of 2C-B in forensic samples is presented with minimal sample consumption (50 μL). |
---|---|
ISSN: | 1759-9660 1759-9679 1759-9679 |
DOI: | 10.1039/d4ay01310g |