Environmentally friendly screen-printed electrodes for the selective detection of 4-bromo-2,5-dimethoxyphenethylamine (2C-B) in forensic analysis

In response to the growing need for sustainable analytical methods, this study explores the repurposing of screen-printed electrodes (SPEs) that would otherwise be discarded. This involves recoating the working electrode surface with a graphite (Gr) and chitosan (CTS) dispersion, creating a reusable...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical methods 2024-11, Vol.16 (44), p.7633-7642
Hauptverfasser: Macedo, Anne Alves, Pimentel, Dilton Martins, Melo, Larissa Magalhães de Almeida, Rocha, Cláudia M, de Fátima, Ângelo, Souza, Karla A O, Costa, Jose L, Arantes, Luciano Chaves, Dos Santos, Wallans Torres Pio
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In response to the growing need for sustainable analytical methods, this study explores the repurposing of screen-printed electrodes (SPEs) that would otherwise be discarded. This involves recoating the working electrode surface with a graphite (Gr) and chitosan (CTS) dispersion, creating a reusable SPE (SPE-Gr/CTS). Demonstrating its utility, SPE-Gr/CTS was employed for the detection of 4-bromo-2,5-dimethoxyphenethylamine (2C-B), a phenylethylamine commonly used for recreational proposes. Identifying 2C-B in fluid oral and seized samples is of great interest for forensic and toxicological applications. The 2C-B detection using SPE-Gr/CTS was optimized in Britton-Robinson buffer solution (0.1 mol L ) at pH 2.0, employing square-wave adsorptive stripping voltammetry. The electrochemical behavior of 2C-B on SPE-Gr/CTS exhibited one irreversible oxidation and a reversible redox process. The proposed method presented a dynamic linear range for 2C-B determination (0.05 to 7.5 μmol L ) with a low LOD (0.015 μmol L ). Moreover, the stability of 2C-B electrochemical responses on SPE-Gr/CTS was confirmed using the same or different electrodes ( = 3), with a relative standard deviation of less than 5.0%. Interference studies with seventeen other illicit drugs and adulterants demonstrated that the proposed method is selective for 2C-B detection even in the presence of these substances. Real seized and oral fluid samples containing 2C-B were analyzed using this method, and the results were confirmed by LC-MS. The proposed device demonstrates to be an environmentally friendly and selective sensor for 2C-B detection in forensic analysis, offering a rapid and straightforward screening method for seized and biological samples. In addition, a portable and sensitive determination of 2C-B in forensic samples is presented with minimal sample consumption (50 μL).
ISSN:1759-9660
1759-9679
1759-9679
DOI:10.1039/d4ay01310g