Anion exchange-HPLC method for evaluating the encapsulation efficiency of mRNA-loaded lipid nanoparticles using analytical quality by design

•Anion-exchange HPLC method development based on Analytical Quality by Design.•Design of Experiments helped establish a robust and sensitive analytical method.•Direct injection of poly(A)-loaded lipid nanoparticle into HPLC.•Optimized HPLC method detects lipid nanoparticle degradation comparable to...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of chromatography. B, Analytical technologies in the biomedical and life sciences Analytical technologies in the biomedical and life sciences, 2024-10, Vol.1247, p.124317, Article 124317
Hauptverfasser: Hara, Shoki, Arase, Shuntaro, Sano, Syusuke, Suzuki, Takuya, Mizogaki, Iori, Sato, Shinya, Ukai, Koji
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Anion-exchange HPLC method development based on Analytical Quality by Design.•Design of Experiments helped establish a robust and sensitive analytical method.•Direct injection of poly(A)-loaded lipid nanoparticle into HPLC.•Optimized HPLC method detects lipid nanoparticle degradation comparable to RiboGreen assay.•Method validation as per ICH Q2 guidelines. Lipid nanoparticles (LNPs) are emerging nucleic acid delivery systems in the development of mRNA therapeutics such as the severe acute respiratory syndrome coronavirus 2 vaccines. However, a suitable analytical method for evaluating the encapsulation efficiency (EE) of the LNPs is required to ensure drug efficacy, as current analytical methods exhibit throughput issues and require long analysis times. Hence, we developed and validated an anion-exchange HPLC method using Analytical Quality by Design. Three critical method parameters (CMPs) were identified using risk assessment and Design of Experiments: column temperature, flow rate, and sodium perchlorate concentration. The CMPs were optimized using Face-Centered Central Composite Design. The discriminating power of the optimized HPLC method and RiboGreen assay was comparable. The main advantage of this method is that LNPs can be directly injected into the HPLC system without bursting the LNPs loaded with encapsulated poly(A). The optimized HPLC method was validated as robust, high-throughput, and sufficiently sensitive according to the ICH Q2 guidelines. We believe our findings could promote efficient LNPs-based drug development.
ISSN:1570-0232
1873-376X
1873-376X
DOI:10.1016/j.jchromb.2024.124317