The Role of Contrast-enhanced Ultrasound in the Femoral Head Perfusion Evaluation: A Pilot Study
We explored the value of contrast-enhanced ultrasound (CEUS) in evaluating femoral head (FH) perfusion, guiding interventions and follow-up for infants with developmental dysplasia of the hip (DDH) and septic arthritis of the hip (SAH). The aim was to provide robust evidence for clinical assessment....
Gespeichert in:
Veröffentlicht in: | Ultrasound in medicine & biology 2024-12, Vol.50 (12), p.1834-1841 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We explored the value of contrast-enhanced ultrasound (CEUS) in evaluating femoral head (FH) perfusion, guiding interventions and follow-up for infants with developmental dysplasia of the hip (DDH) and septic arthritis of the hip (SAH). The aim was to provide robust evidence for clinical assessment.
Ten infants, including 7 with DDH and 3 with SAH, were prospectively enrolled, with their bilateral hips alternately scanned during the CEUS exams. Twenty hips were classified into the case group (n = 11) and the control group (n = 9). Pre- and post-interventional studies were performed in DDH infants requiring interventions. FH perfusion was assessed by the perfusion area ratio (PAR) and quadrant location of microbubble-defect regions.
In the case group, 25 CEUS studies were conducted, including 11 baseline, 7 follow-up and 7 post-intervention studies. The PAR significantly decreased in the case group (49.79% vs. 100.00%, p < 0.05). The microbubble-defect regions averagely affected 2 quadrants, primarily quadrat No. 3 (30%) and No. 4 (32%). Seven hip abduction angle adjustments were made based on pre-interventional studies, resulting in a significant increase in PAR in post-interventional studies (37.63% vs. 60.24%, p < 0.05). PAR increased in follow-up studies compared to baseline values (45.61% vs. 76.07%, p < 0.05). The inter- and intra-observer reproducibility of PAR measurements were excellent (intraclass correlation coefficient, both 0.97).
CEUS proves to be a promising technique for quantitatively detecting FH perfusion in DDH and SAH infants with high reproducibility. It is valuable for baseline, intra-intervention and follow-up studies, aiming in clinical conditions and therapeutic effect evaluation. |
---|---|
ISSN: | 0301-5629 1879-291X 1879-291X |
DOI: | 10.1016/j.ultrasmedbio.2024.08.005 |