The portable stochastic sensor as a screening tool for simultaneous determination of HER-1 and CA 125 — a key factor in the rapid recognition of gastric cancer

The significance of HER-1 and CA 125 lies in their ability to guide cancer diagnosis, treatment, and monitoring, improving personalized care and enhancing prognostic accuracy. The utilization of HER-1 and CA 125 as screening biomarkers for the anticipation of early-stage cancer and monitoring cancer...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Mikrochimica acta (1966) 2024-10, Vol.191 (10), p.597, Article 597
Hauptverfasser: Comnea-Stancu, Ionela Raluca, Georgescu-State, Ramona, Stefan-van Staden, Raluca-Ioana, State, Razvan Nicolae, Ilie-Mihai, Ruxandra-Maria
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The significance of HER-1 and CA 125 lies in their ability to guide cancer diagnosis, treatment, and monitoring, improving personalized care and enhancing prognostic accuracy. The utilization of HER-1 and CA 125 as screening biomarkers for the anticipation of early-stage cancer and monitoring cancer progression is expanding due to the invasive and costly nature of present techniques. In this study, a novel stochastic sensor was developed for the simultaneous determination of HER-1 and CA 125 in whole blood, saliva, and gastric tumor tissue samples using a fast, easy, inexpensive, and portable method. The stochastic sensor was prepared by electropolymerization of cysteine on the surface of the Au-TiO 2 @rGO/SPCE sensor. The Au-TiO 2 @rGO nanocomposite was synthesized using a simple chemical reduction process. The proposed sensor showed wide linear concentration ranges and very low limits of quantification (LOQ). The concentration ranges were from 3.9 × 10 −14 to 3.9 × 10 −8  µg mL −1 , with a LOQ of 3.9 × 10 −14  µg mL −1 for HER-1. For CA 125, the concentration ranges were from 8.3 × 10 −14 to 8.3 × 10 −10 U mL −1 , with a LOQ of 8.3 × 10 −14 U mL −1 . Both biomarkers exhibit precise discrimination in different biological samples, with recoveries above 96.78% and RSD values below 0.04%. With a confidence level of 99%, the Student t -test revealed that there is no statistically significant difference between the outcomes obtained by using the poly-Cys/Au-TiO 2 @rGO/SPCE sensor for screening examinations of biological samples. This was determined because the results were not significantly different from one another. Graphical Abstract
ISSN:0026-3672
1436-5073
1436-5073
DOI:10.1007/s00604-024-06674-w