The portable stochastic sensor as a screening tool for simultaneous determination of HER-1 and CA 125 — a key factor in the rapid recognition of gastric cancer
The significance of HER-1 and CA 125 lies in their ability to guide cancer diagnosis, treatment, and monitoring, improving personalized care and enhancing prognostic accuracy. The utilization of HER-1 and CA 125 as screening biomarkers for the anticipation of early-stage cancer and monitoring cancer...
Gespeichert in:
Veröffentlicht in: | Mikrochimica acta (1966) 2024-10, Vol.191 (10), p.597, Article 597 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The significance of HER-1 and CA 125 lies in their ability to guide cancer diagnosis, treatment, and monitoring, improving personalized care and enhancing prognostic accuracy. The utilization of HER-1 and CA 125 as screening biomarkers for the anticipation of early-stage cancer and monitoring cancer progression is expanding due to the invasive and costly nature of present techniques. In this study, a novel stochastic sensor was developed for the simultaneous determination of HER-1 and CA 125 in whole blood, saliva, and gastric tumor tissue samples using a fast, easy, inexpensive, and portable method. The stochastic sensor was prepared by electropolymerization of cysteine on the surface of the Au-TiO
2
@rGO/SPCE sensor. The Au-TiO
2
@rGO nanocomposite was synthesized using a simple chemical reduction process. The proposed sensor showed wide linear concentration ranges and very low limits of quantification (LOQ). The concentration ranges were from 3.9 × 10
−14
to 3.9 × 10
−8
µg mL
−1
, with a LOQ of 3.9 × 10
−14
µg mL
−1
for HER-1. For CA 125, the concentration ranges were from 8.3 × 10
−14
to 8.3 × 10
−10
U mL
−1
, with a LOQ of 8.3 × 10
−14
U mL
−1
. Both biomarkers exhibit precise discrimination in different biological samples, with recoveries above 96.78% and RSD values below 0.04%. With a confidence level of 99%, the Student
t
-test revealed that there is no statistically significant difference between the outcomes obtained by using the poly-Cys/Au-TiO
2
@rGO/SPCE sensor for screening examinations of biological samples. This was determined because the results were not significantly different from one another.
Graphical Abstract |
---|---|
ISSN: | 0026-3672 1436-5073 1436-5073 |
DOI: | 10.1007/s00604-024-06674-w |