Lumbar Spine Densitometry in People with Spinal Cord Injury: Investigation of Potential Sources of Errors
Purpose: People with spinal cord injury (SCI) experience a considerable loss of bone after the injury. Lumbar spine (LS) bone mineral density (BMD) has been reported to be within the normal range, or even higher when assessed with DXA, in people with SCI; hence, it has been hypothesized that sources...
Gespeichert in:
Veröffentlicht in: | Journal of clinical densitometry 2024-10, Vol.27 (4), p.101528, Article 101528 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose: People with spinal cord injury (SCI) experience a considerable loss of bone after the injury. Lumbar spine (LS) bone mineral density (BMD) has been reported to be within the normal range, or even higher when assessed with DXA, in people with SCI; hence, it has been hypothesized that sources of error may spuriously increase LS BMD. The aim of this study was to describe the frequency of potential sources of error that may alter LS BMD measurement in a cohort of individuals with chronic SCI at baseline and over a 2-year period. Methods: We analyzed baseline and 2-year follow up DXA scans (Hologic Discovery QDR 4500, Hologic Inc., MA, USA) previously performed from a cohort of males and females with chronic SCI. Two physicians independently reviewed each scan, commented on whether the scan was appropriate for BMD analysis, should be re-analyzed, or be removed from the dataset, and reported on the presence of potential sources of error in LS BMD measurement. Results: We reviewed 115 lumbar spine DXA scans from 58 participants, and 107 (93.0 %) scans from 52 participants presented at least one potential source of error. At baseline, the average number of potential sources of error per scan was 5.5 ± 1.7 and 5.7 ± 1.5 according to rater 1 and rater 2, respectively. Follow-up scans presented an average of 5.6 ± 1.6 and 5.7 ± 1.4 potential sources of error according to rater 1 and rater 2, respectively. Facet sclerosis, osteophytes and difficulty in detecting bone edges were the most prevalent sources of error. Conclusion: The high frequency of potential sources of error is consistent with current recommendations against the use of LS BMD for fracture risk assessment in people with SCI. |
---|---|
ISSN: | 1094-6950 |