Double low-dose computed tomography (CT) angiography of craniocervical arteries using a test bolus of diluted contrast medium and a personalized contrast protocol
To prospectively assess the value of a test bolus of diluted contrast medium (CM) combined with a personalized contrast protocol in craniocervical computed tomography angiography (cc-CTA) with low radiation and CM doses. Eighty-six consecutive subjects were divided into two groups at random (43 in e...
Gespeichert in:
Veröffentlicht in: | Clinical radiology 2024-11, Vol.79 (11), p.e1330-e1338 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To prospectively assess the value of a test bolus of diluted contrast medium (CM) combined with a personalized contrast protocol in craniocervical computed tomography angiography (cc-CTA) with low radiation and CM doses.
Eighty-six consecutive subjects were divided into two groups at random (43 in each one): group A: 100/Sn140 kVp, filtered back-projection reconstruction, iopromide (370 mgI/ml) 50 ml; group B: 80/Sn140 kVp, iterative reconstruction, iodixanol (270 mgI/ml). In group B, the test bolus contained 27 ml of diluted CM, a personalized protocol with low-concentration CM was used for angiography, and the test bolus injection duration in angiography remained the same. Artery values over 200 Hounsfield units were considered significant.
Image quality for all cases was found to be diagnostic. No significant differences were found in the arterial densities of the ascending aorta or basilar artery between the groups. The values of the common carotid artery, internal carotid artery, and middle cerebral artery in group B were significantly lower. The effective dose and average iodine uptake were significantly lower in group B.
With double-low-dose cc-CTA, test bolus scanning based on diluted CM combined with a personalized contrast protocol can yield diagnostic-quality images and significantly reduce the radiation and CM doses.
•Test bolus with diluted contrast medium (CM) allows for precise anticipation of the scan trigger time.•A personalized CM protocol made it feasible to further reduce iodine uptake.•The double low dose protocol can get images with diagnostic quality in craniocervical computed tomography angiography. |
---|---|
ISSN: | 0009-9260 1365-229X 1365-229X |
DOI: | 10.1016/j.crad.2024.07.021 |