A transcranial multiple waves suppression method for plane wave imaging based on Radon transform

•Developed a multiple wave suppression method using enhanced Radon transform for transcranial ultrasound imaging, addressing skull interference complexities.•Demonstrated efficacy in separating intracranial reflections from strong skull reflections, enabling velocity-corrected imaging.•Tackles the c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ultrasonics 2024-09, Vol.143, p.107405, Article 107405
Hauptverfasser: Pan, Yue, Qiang, Yu, Liang, Wenjie, Huang, Wenyue, Wang, Ningyuan, Wang, Xingying, Zhang, Zhiqiang, Qiu, Weibao, Zheng, Hairong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Developed a multiple wave suppression method using enhanced Radon transform for transcranial ultrasound imaging, addressing skull interference complexities.•Demonstrated efficacy in separating intracranial reflections from strong skull reflections, enabling velocity-corrected imaging.•Tackles the challenge of wavefield separation in transcranial ultrasound.•Improves the imaging quality and diagnostic accuracy in neurological research and clinical applications. Transcranial ultrasound imaging presents a significant challenge due to the intricate interplay between ultrasound waves and the heterogeneous human skull. The skull’s presence induces distortion, refraction, multiple scattering, and reflection of ultrasound signals, thereby complicating the acquisition of high-quality images. Extracting reflections from the entire waveform is crucial yet exceedingly challenging, as intracranial reflections are often obscured by strong amplitude direct waves and multiple scattering. In this paper, a multiple wave suppression method for ultrasound plane wave imaging is proposed to mitigate the impact of skull interference. Drawing upon prior research, we developed an enhanced high-resolution linear Radon transform using the maximum entropy principle and Bayesian method, facilitating wavefield separation. We detailed the process of wave field separation in the Radon domain through simulation of a model with a high velocity layer. When plane waves emitted at any steering angles, both multiple waves and first arrival waves manifested as distinct energy points. In the brain simulation, we contrasted the characteristic differences between skull reflection and brain-internal signal in Radon domain, and demonstrated that multiples suppression method reduces side and grating lobe levels by approximately 30 dB. Finally, we executed in vitro experiments using a monkey skull to separate weak intracranial reflection signals from strong skull reflections, enhancing the contrast-to-noise ratio by 85 % compared to conventional method using full waveform. This study deeply explores the effect of multiples on effective signal separation, addresses the complexity of wavefield separation, and verifies its efficacy through imaging, thereby significantly advancing ultrasound transcranial imaging techniques.
ISSN:0041-624X
1874-9968
1874-9968
DOI:10.1016/j.ultras.2024.107405