3-Year Outcomes From the Evolut Low Risk TAVR Bicuspid Study

Outcomes from transcatheter aortic valve replacement (TAVR) in low–surgical risk patients with bicuspid aortic stenosis beyond 2 years are limited. This study aimed to evaluate 3-year clinical and echocardiographic outcomes from the Evolut Low Risk Bicuspid Study. The Evolut Low Risk Bicuspid Study...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JACC. Cardiovascular interventions 2024-07, Vol.17 (14), p.1667-1675
Hauptverfasser: Zahr, Firas, Ramlawi, Basel, Reardon, Michael J., Deeb, G. Michael, Yakubov, Steven J., Song, Howard K., Kleiman, Neal S., Chetcuti, Stanley J., Gada, Hemal, Mumtaz, Mubashir, Leung, Stephane, Merhi, William, Rovin, Joshua D., DeFrain, Michael, Muppala, Murali, Kauten, James, Rajagopal, Vivek, Huang, Jiang, Ito, Saki, Forrest, John K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Outcomes from transcatheter aortic valve replacement (TAVR) in low–surgical risk patients with bicuspid aortic stenosis beyond 2 years are limited. This study aimed to evaluate 3-year clinical and echocardiographic outcomes from the Evolut Low Risk Bicuspid Study. The Evolut Low Risk Bicuspid Study is a prospective, multicenter, single-arm study conducted in 25 U.S. centers. Patients with severe aortic stenosis at low surgical risk with bicuspid aortic valve anatomy (all subtypes) underwent TAVR with a self-expanding, supra-annular Evolut R or PRO (Medtronic) bioprosthesis. An independent clinical events committee adjudicated all deaths and endpoint-related adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. An attempted implant was performed in 150 patients from December 2018 to October 2019. The mean age was 70.3 ± 5.5 years, 48% (72/150) of the patients were women, and the mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 1.3% (Q1-Q3: 0.9%-1.7%). Sievers type 1 was the dominant bicuspid morphology (90.7%, 136/150). The Kaplan-Meier rates of all-cause mortality or disabling stroke were 1.3% (95% CI: 0.3%-5.3%) at 1 year, 3.4% (95% CI: 1.4%-8.1%) at 2 years, and 4.1% (95% CI: 1.6%-10.7%) at 3 years. The incidence of new permanent pacemaker implantation was 19.4% (95% CI: 12.4%-29.6%) at 3 years. There were no instances of moderate or severe paravalvular aortic regurgitation at 2 and 3 years after TAVR. The 3-year results from the Evolut Low Risk Bicuspid Study demonstrate low rates of all-cause mortality or disabling stroke and favorable hemodynamic performance. [Display omitted]
ISSN:1936-8798
1876-7605
1876-7605
DOI:10.1016/j.jcin.2024.05.017