A Data-Driven Design Framework for Structural Optimization to Enhance Wearing Adaptability of Prosthetic Hands
Prosthetic hands have significant potential to restore the manipulative capabilities and self-confidence of amputees and enhance their quality of life. However, incompatibility between prosthetic devices and residual limbs can lead to secondary injuries such as skin pressure ulcers and restricted jo...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on neural systems and rehabilitation engineering 2024, Vol.32, p.2621-2632 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Prosthetic hands have significant potential to restore the manipulative capabilities and self-confidence of amputees and enhance their quality of life. However, incompatibility between prosthetic devices and residual limbs can lead to secondary injuries such as skin pressure ulcers and restricted joint motion, contributing to a high prosthesis abandonment rate. To address these challenges, this study introduces a data-driven design framework (D3Frame) utilizing a multi-index optimization method. By incorporating motion/ pressure data, as well as clinical criteria such as pain threshold/ tolerance, from various anatomical sites on the residual limbs of amputees, this framework aims to optimize the structural design of the prosthetic socket, including the Antecubital Channel (AC), Lateral Epicondylar Region Contour (LC), Medial Epicondylar Region Contour (MC), Olecranon Region Contour (OC), Lateral Flexor/ Extensor Region (LR), and Medial Flexor/ Extensor Region (MR). Experiments on five forearm amputees verified the improved adaptability of the optimized socket compared to traditional sockets under three load conditions. The experimental results revealed a modest score enhancement on standard clinical scales and reduced muscle fatigue levels. Specifically, the percent effort of muscles and slope value of mean/ median frequency decreased by 19%, 70%, and 99% on average, respectively, and the average values of mean/ median frequency in the motion cycle both increased by approximately 5%. The proposed D3Frame in this study was applied to optimize the structural aspects of designated regions of the prosthetic socket, offering the potential to aid prosthetists in prosthesis design and, consequently, augmenting the adaptability of prosthetic devices. |
---|---|
ISSN: | 1534-4320 1558-0210 1558-0210 |
DOI: | 10.1109/TNSRE.2024.3430070 |