Marginal integrity of prototype bioactive glass-doped resin composites in class II cavities

Objectives This in vitro study examined the marginal integrity of experimental composite materials doped with bioactive glass (BG). Materials and methods Class-II MOD cavities were prepared and restored with one of the following composite materials: a commercial composite material as a reference (Fi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical oral investigations 2024-07, Vol.28 (8), p.430, Article 430
Hauptverfasser: Mohn, Nike, Par, Matej, Gubler, Andrea, Tauböck, Tobias T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectives This in vitro study examined the marginal integrity of experimental composite materials doped with bioactive glass (BG). Materials and methods Class-II MOD cavities were prepared and restored with one of the following composite materials: a commercial composite material as a reference (Filtek Supreme XTE), an experimental composite doped with BG 45S5 (C-20), and an experimental composite doped with a fluoride-containing BG (F-20). Six experimental groups ( n  = 8) were used, as each of the three composites was applied with (+) or without (-) a universal adhesive (Adper Scotchbond Multipurpose). All specimens were subjected to thermocycling (10,000 x, 5–55 °C) and then additionally stored in artificial saliva for eight weeks. Scanning electron micrographs of the mesial and the distal box were taken at three time points (initial, after thermocycling, and after eight weeks of storage in artificial saliva). The margins were classified as “continuous” and “non-continuous” and the percentage of continuous margins (PCM) was statistically analyzed (α = 0.05). Results In most experimental groups, thermocycling led to a significant decrease in PCM, while the additional 8-week aging had no significant effect. F-20 + performed significantly better ( p  = 0.005) after 8 weeks storage in artificial saliva than the reference material with adhesive, while no statistically significant differences were observed at the other two time points. C-20 + exhibited significantly better PCM than the reference material with adhesive after thermocycling ( p  = 0.026) and after 8 weeks ( p  = 0.003). Conclusions Overall, the experimental composites with BG showed at least as good marginal adaptation as the commercial reference, with an indication of possible re-sealing of marginal gaps. Clinical relevance Maintaining or improving the marginal integrity of composite restorations is important to prevent microleakage and its likely consequences such as pulp irritation and secondary caries.
ISSN:1436-3771
1432-6981
1436-3771
DOI:10.1007/s00784-024-05824-x