Quality assurance and other challenges in paediatric radiotherapy: Accurate delivery of craniospinal radiotherapy
Cranio-spinal radiotherapy (CSI) is used to treat central nervous system malignancies in paediatric, adolescent/young adult (AYA), and adult patients. Its delivery in the paediatric/AYA population is particularly challenging across different age groups. This study aims to assess the setup variations...
Gespeichert in:
Veröffentlicht in: | Journal of medical imaging and radiation oncology 2024-07 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Cranio-spinal radiotherapy (CSI) is used to treat central nervous system malignancies in paediatric, adolescent/young adult (AYA), and adult patients. Its delivery in the paediatric/AYA population is particularly challenging across different age groups. This study aims to assess the setup variations and dosimetric impact of CSI in paediatric and AYA patients.
This retrospective analysis included, 10 paediatric and AYA patients (aged 4-25) who underwent volumetric modulated arc therapy (VMAT) CSI between 2016 and 2022. Patient characteristics, diagnoses, prescribed CSI doses, and fractionation details were assessed. CT simulation and treatment planning followed standard protocols with setup errors were quantified by comparing daily treatment setup images with the planned position. The study evaluated the dosimetric impact on target volumes and organs at risk (OARs).
The setup errors were identified, ranging from 0.5 to 6.2 mm in different directions, especially in the cranio-caudal direction. Despite these variations, there was minimal impact observed on the coverage of clinical target volumes (CTV) and doses to OARs ( |
---|---|
ISSN: | 1754-9477 1754-9485 1754-9485 |