Transcatheter and Surgical Ductus Arteriosus Closure in Very Low Birth Weight Infants: 2018-2022

The optimal patent ductus arteriosus (PDA) closure method in very low birth weight (VLBW) infants is uncertain. In 2019, the first transcatheter occlusion device was approved in the United States for infants ≥700 g. We described survival and short-term outcomes among VLBW infants who underwent trans...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Pediatrics (Evanston) 2024-08, Vol.154 (2), p.1
Hauptverfasser: Leahy, Brianna F, Edwards, Erika M, Ehret, Danielle E Y, Soll, Roger F, Yeager, Scott B, Flyer, Jonathan N
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The optimal patent ductus arteriosus (PDA) closure method in very low birth weight (VLBW) infants is uncertain. In 2019, the first transcatheter occlusion device was approved in the United States for infants ≥700 g. We described survival and short-term outcomes among VLBW infants who underwent transcatheter or surgical PDA closure (2018-2022). Vermont Oxford Network members submitted data on infants born from 401 to 1500 g or 22 to 29 weeks' gestational age. Adjusted risk ratios (aRR) for survival, length of stay (LOS), prematurity complications, and discharge support were used to compare transcatheter versus surgical closure. Subgroup analyses were conducted for infants with birth weight ≥700 g and born in 2020-2022. Overall, 6410 of 216 267 infants at 726 hospitals received invasive PDA treatment. Transcatheter closure increased from 29.8% in 2018 to 71.7% in 2022. VLBW infants undergoing transcatheter closure had higher survival (adjusted rate ratio [aRR] 1.03; 1.02-1.04) with similar LOS (aRR 1.00; 0.97-1.03), neonatal complications (aRR 1.00; 0.98-1.01), and receipt of discharge support (aRR 0.94; 0.89-1.01). In subgroup analyses, survival (aRR 1.02; 1.00-1.04) and discharge support (aRR 0.90; 0.81-1.01) were similar between groups, whereas selected neonatal complications (aRR 0.95; 0.93-0.98) and LOS (aRR 0.95; 0.90-0.99) were lower after transcatheter closure. Transcatheter PDA closure in VLBW infants was increasingly used after 2018. Selected short-term outcomes for infants receiving transcatheter closure may be more favorable, compared with surgical, and warrants further clinical investigation.
ISSN:0031-4005
1098-4275
1098-4275
DOI:10.1542/peds.2024-065905